Fisher FSL-1100B-H-3F Operation Manual

The ducted split type air-conditioning units

Advertisement

Quick Links

Operation Manual of The Ducted Split
Type Air-Conditioning Units
FSL-1100B-H-3F
FSOL-1100B-3F
Please read this manual carefully before operation and installation

Advertisement

Table of Contents
loading

Summary of Contents for Fisher FSL-1100B-H-3F

  • Page 1 Operation Manual of The Ducted Split Type Air-Conditioning Units FSL-1100B-H-3F FSOL-1100B-3F Please read this manual carefully before operation and installation...
  • Page 2 Any violation of the precedent items will lead to the invalidation of guarantee. All of the figures and messages are for reference only. Since The FISHER has a policy of continuous product improvement, he reserves the right to change design and specifications of the products at any time without notice.
  • Page 3: Table Of Contents

    CONTENTS Preface ..............................0 1、Safety precautions .......................... 1 2、Displaying Part ..........................3 2.1 LCD Display of Wired Controller........................3 2.2 Instruction to LCD Display..........................3 3、Buttons ............................. 5 3.1 Silk Screen of Buttons ..........................5 3.2 Instruction to Function of Buttons .......................5 4、Installation of Wired Controller and Project Debugging .............. 7 4.1 Installation of Wired Controller ........................7 5、Instruction to Operation........................
  • Page 4: Safety Precautions

    1、Safety precautions 1.1 Safety notice Before using the appliance, read this manual thoroughly and operate under its direction. “WARNING” and “ATTENTION” have the following meanings in these instructions: △WARNING This mark indicates procedures, which if improperly performed, might lead to the death or serious injury of the users.
  • Page 5 The appliance shall be installed in accordance with national wiring regulations The temperature of refrigerant circuit will be high, please keep the interconnection cable away from the copper tube.
  • Page 6: Displaying Part

    2、Displaying Part Fig.2.1 Outline of wired controller 2.1 LCD Display of Wired Controller Fig.2.2 LCD display 2.2 Instruction to LCD Display Description Instruction to Displaying Contents Swing Swing function Air exchange function Sleep Sleeping states Running Each kind of running mode of indoor unit (auto mode)
  • Page 7 mode Cooling Cooling mode Dry mode Heating Heating mode Defrost Defrosting state Gate-control Gate control card Lock ock state Shielding state (buttons, temperature, on/off, mode or save is shielded by Shield long-distance monitoring Turbo Turbo function state Memory state (Indoor unit resumes original setting state after power failure Memory and then power recovery) Twinkle...
  • Page 8: Buttons

    3、Buttons 3.1 Silk Screen of Buttons Fig. 3.1 Silk screen of buttons 3.2 Instruction to Function of Buttons Description Function of Button Enter/cance (1)Function selection and canceling; (2)Press it for 5s to enquiry the outdoor ambient temperature. (1) Running temperature setting of indoor unit, range :16~30℃ ▲...
  • Page 9 Upon startup of the unit without malfunction or under off state of the unit, press ▲ Lock them at the same time for 5s in to lock state. In this case, any other buttons won’t respond the press. Repress them for 5s to quit lock state. ▼...
  • Page 10: Installation Of Wired Controller And Project Debugging

    4、Installation of Wired Controller and Project Debugging 4.1 Installation of Wired Controller Fig.4.1: Sketch for Installation of Wired Controller Description Socket’s base Soleplate of Screw M4X25 Front panel of Screw box installed in controller controller ST2.2X6.5 the wall Fig.4.1: Sketch for Installation of Wired Controller. Pay attention to the following items during installation of wired controller: 1.
  • Page 11 them should be kept 20cm in min. 2. If the unit is installed at the place where there is interference of electromagnetism, signal line and wiring (communication) of wired controller must be shielding twisted pair lines.
  • Page 12: Instruction To Operation

    5、Instruction to Operation 5.1 On/Off Press On/Off button to turn on the unit. Repress this button to turn off the unit. Note: The state shown in Fig.5.1 indicates off state of the unit after energization. The state shown in Fig.5.2 indicates on state of the unit after energization. Fig.5.1 Off state of the unit Fig.5.2 On state of the unit 5.2 Mode Setting...
  • Page 13: Fan Speed Setting

    Fig 5.3 5.4 Fan Speed Setting * Under on/off state of the unit, press Fan button, fan speed of indoor unit will change as below: As shown in Fig.5.4 Fig.5.4 (Indoor unit can only run at high fan speed mode and fan speed can’t be modified by wired controller.) 5.5 Swing Control Function * Under on state of unit, press Function button till the unit enters swing control function and then press “Enter/cancel “...
  • Page 14: Timer Setting

    Fig.5.5 5.6 Timer Setting Under on state of the unit, press Timer button to set timer off of the unit. Under off state of the unit, press Timer button to set timer on of the unit in the same way. Timer on setting: Under off state of the unit without timer setting, if Timer button is pressed, LCD will display xx.
  • Page 15: Air Exchange Setting

    Fig.5.6 Timer setting under on state of the unit Timer range: 0.5-24hr. Every press of▲ or ▼ button will make setting time increased or decreased by 0.5hr.If press either of them continuously, setting time will automatically increase/ decrease by 0.5hr every 0.5s. Note: 1.
  • Page 16: Sleep Setting

    5――The unit continuously runs for 60min, and fresh air valve runs for 30 min. 6――The unit continuously runs for 60min, and fresh air valve runs for 36 min. 7――The unit continuously runs for 60min, and fresh air valve runs for 42 min. 8――The unit continuously runs for 60min, and fresh air valve runs for 48 min.
  • Page 17: Turbo Function Setting

    Fig.5.8 Sleep setting Sleep off is default after power failure and then power recovery. There is not sleep function in fan and auto mode. Note: In cooling and dry mode, if the unit with sleep function has run for 1 hour, the preset temperature will be increased by 1℃...
  • Page 18: Save Function Setting

    Fig.5.9 Turbo Function Setting Note: 1. Turbo function will be turned off after power failure and then recovery. In dry, fan and auto mode, turbo function can not be set and turbo mark won’t be displayed. 2. Turbo function will be automatically canceled after setting of quiet function. 5.10 Save Function Setting Energy Saving Function: Energy saving result that the air conditioner runs in smaller temperature...
  • Page 19: E-Heater Setting

    Fig.5.10 Energy Saving Setting Note: 1.In Auto running mode with save function on, the unit will be forcibly changed to corresponding mode. After setting of save, sleep function will be canceled. 2. In save mode, if Function button is pressed or there is not any operation within 5s after the last button operation, the system will quit from save function setting and current data won’t be memorized.
  • Page 20: Blow Function Setting

    If auxiliary electric heating function is on, press Function button to confirm or press Enter/cancel button to cancel. In this case, E-HEATER won’t be displayed, which means E-heater is prohibited to be turned on. The setting of this function is shown as Fig.5.11 below: Fig.
  • Page 21: Quiet Function Setting

    Fig.5.12 Blow function setting Note: 1.After setting dry function, turn off the unit by pressing On/Off button or remote controller, indoor fan will run at low fan speed for 10 min. (BLOW shows).Meanwhile, if dry function is canceled indoor fan will be turned off directly.
  • Page 22: Debugging Functions

    Fig.5.13 Quiet function setting Note: 1. During quiet function, fan speed is un-adjustable. 2. When turning on auto quiet function, the unit will enter quiet running state according to temperature difference between room temperature and setting temperature. In this case, fan speed is adjustable.
  • Page 23: Three Grades Of Speed For Indoor Fan

    ②Indoor ambient temperature is that at the place of displayer (02 is displayed at timer displayed location) ③Return air inlet temperature sensor shall be selected for cooling, dry and fan modes and wired controller temperature sensor (03 is displayed at timer displayed location) shall be selected for heating and auto modes.
  • Page 24: Enquiry Of Outdoor Ambient Temperature

    card. If memory function is on, the unit after plugging out of card and then plugging in will run according to the memory. If the card is not plugged in (or poor plugging), the mark will show and the unit will be turned off.
  • Page 25: Error Display

    6、Error Display If there is malfunction during running of the system, LCD will display error code at temperature–displayed location. Once many malfunctions, error codes will be displayed circularly. If there are multiple systems, the system number of failed system will be displayed before the colon (not for single system).
  • Page 26 Error code meaning: Malfunction Error code Water pump malfunction High pressure protection of compressor Indoor anti-freezing protection Low pressure protection of compressor High discharge temperature protection of compressor Compressor overload protection Communication malfunction Indoor fan motor protection Indoor unit ambient sensor malfunction at air return opening Evaporator sensor malfunction Condenser sensor malfunction...
  • Page 27: Names And Functions Of Remote Control Buttons

    7、Names and functions of remote control buttons Notes: This remote control is universal .It could be used for many units. Some buttons which are not available in this unit will not be described below. 1. “ON/OFF” button After powering the unit, when the unit is off state, press the “ON/OFF” button to start the unit. AND when the unit is on state, press the button ,it will be off.
  • Page 28 5、 button * There is no this function for this unit. If press this key, the main unit will click, but it also runs under original status. 6、 button There is no this function for this unit. If press this key, the main unit will click, but it also runs under original status.
  • Page 29 About AUTO RUN : When AUTO RUN mode is selected, the setting temperature will not be displayed on the LCD .The unit will be accordance with the room temp, automatically to select the suitable running mode and to make ambient comfortable. About turbo function If start this function, the unit will run at super-high speed to cool or heat quickly so that the ambient temp approachs the preset temp as soon as possible.
  • Page 30: Changing Batteries And Notices

    8、Changing batteries and notices 1、 Slightly to press the place with along the arrowhead direction to push the back cover of remote controller.(As show in Fig 8.1.) Fig 8.1 2、 Take out the old batteries ,insert two AAA alkaline cells(As show in Fig 8.2.) 3、Attach the back cover of remote control.
  • Page 31: Weekly Timer Function

    9、Weekly Timer Function 7DP - Seven days programmer (Accessory not supplied) Centralized Control and Week Timer Functions: The centralized controller and the weekly timer are integrated in the same wire controller. The system has both the centralized control and the week timing functions.
  • Page 32 Note: 1. For upper unit checks 16 lower units consecutively, there will be no more than 16 seconds delay when setting works till unit responds. 2. Please let us know your requirement before your placing the order, for this WEEKLY TIMER will only be prepared when customer orders(communication joint with WEEKLY TIMER on manual control had been prepared).
  • Page 33: Installation Instruction

    10、Installation instruction The installation must accord with local regulation, and must be carried out by the professionals. Never carry out the work by yourself without the help of professionals. And don’t supply power, until all the work is finished according to the user’s manual. 10.1 Selection proper installation location 1).
  • Page 34 1560 1194 1194 FSL-1100B-H-3F 2).Main body of the indoor unit The indoor unit should be installed horizontally and the demand of installation space is shown in Fig. 20. To install an indoor unit needs 4 hanging rods, and each hanging rod should at least withstand four times of the unit’s weight.
  • Page 35 Drain hose Water seal 4). Refrigerant pipe insulation layer To avoid condensation of drew and water leakage, gas pipe and liquid pipe of refrigerant should be insulated with thermal insulation material and adhesive tape. 5). Install the Electrical Box. (Be Suit For 25KW~40KW) In order to ease the maintaining work, we recommend to get of the electrical box part of the indoor unit to refix it at the air outlet part.
  • Page 36 PVC pipe Fig.24 Schematic Fig. 22 Cable of Fig.23 Cable of concealed installation direct installation Serial Name Wall Soleplate Screw M4X10 Controller Panel 7). Connection of the signal wire Open the electrical box; Plug the wire through the PVC pipe; Plug the wire onto the four-nail sea;...
  • Page 37 Fuse Model code Indoor T5AL 250V 46010013 FSL-1100B-H-3F Outdoor T3.15AL 250V 46010014 FSOL-1100B-3F 11). Adjust the tightness of the belt of the fan unit (Be Suit For 25KW~40KW) The rotation of the fan is achieved by the transmission of the belt. The velocity and stability of the fan is associated with the tightness of the belt and the tightness should be adjusted after a period of time.
  • Page 38: Install The Outdoor Unit

    Belt tensiometer Nut 1 Nut 2 Setting lever Fig. 25 Adjust the tightness of the belt Fig. 26 Utilization of the belt tensiometer 10.3 Install the outdoor unit 1). Outline and dimension of the outdoor unit B±2 C±2 FSOL-1100B-3F Fig 27 Schematic of the Outdoor unit Table.3 Outlines and dimension of the unit Unit: mm Model...
  • Page 39 2). Installation position Side with Electrical Box >1200 >1000...
  • Page 40 Fig 29 Schematic for the installation of the outdoor unit >300 >300 >300 Fig 30 Schematic for the installation of the outdoor unit Fig 31 Crane way schematic When removing the outdoor unit, two ropes are needed to hang the unit along the four ways. In order to avoid the excursion, the angle between the ropes should be less than 40 degree.
  • Page 41 and the number of bends, and enlarge the diameter of bends. The permitted maximum value of each case: Height difference between the indoor and outdoor unit <30M Number of bends <12 Length of connecting pipes <50M The pipe meld type could be employed for the connection of the pipes between the indoor and outdoor units.
  • Page 42: Electric Wiring

    Gas Pipe Pipe Length 7.5m) 110g/m FSOL-1100B-3F,FSL-1100B-H-3F 10.4 Electric wiring All of the supplied components, material, and electric operation should be accorded with the local principles. The power supply should adopt the rated voltage and special circuit for the ducted air-conditioning unit.
  • Page 43 * The power cord must be copper inside, while the working temp. can not be over its standard one. * If the total length of the power cord is over 15m, please increase the size by certain degree. * Please confirm the other wire according to the actual need.
  • Page 44: Trial Run And Installation Checking

    Ducted 2.The electricity leakage switch is switching 2. Contact the service center of conditioni FISHER off for the leakage of electricity from the unit air conditioner units 3. Contact the dealer 3. The voltage is too low 4.
  • Page 45 6. Refrigerant leakage 7. Change room sensor 7. Poor performance of room sensor Note: Check the previous items, please contact the nearest service center of FISHER and depict the air conditioner model and its symptom if the problem cannot be solved.
  • Page 46: Care And Maintenance

    Attention: When you perform leakage test, please do not charge oxygen or acetylene into the system, use nitrogen gas or the refrigerant instead. Service If there is any problem with FISHER ducted air-conditioning units, please contact the local service center or FISHER .
  • Page 47: Appendix

    13、Appendix Air conditioner nominal working condition and working range: Test condition Indoor side Outdoor side DB(℃) WB(℃) DB(℃) WB(℃) Nominal cooling Nominal heating Rated cooling Min. temp. for cooling 18(-15) Rated heating Min. temp. for heating Note: 1. The design of this unit conforms to the requirements of EN14511 standard. 2.
  • Page 48 DISPOSAL : Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary. 66129906995...