Timer range: 0.5-24hr. Every press of▲ or ▼ button will make setting time increased or decreased by 0.5hr.
If press either of them continuously, setting time will automatically increase/ decrease by 0.5hr every 0.5s.
Note:
● If both timer on and timer off are set in unit on interface, the wired controller only display time of time
off. If both of them are set in unit off-state, only time of timer on is displayed.
● Timer on in unit on-state is timed from the time of unit off and timer off in unit off-state is timed from the
time of unit on.
4.7 Air Exchange Setting *
Turn on air Exchange function:
Under on-state of the unit, press Function button to go to this function setting (Air mark blinks).AIR
1 displayed at the ambient temperature-displayed location (888) is defaulted (the last type of AIR will be
displayed after adjustment).Press ▲ or ▼ button to adjust air type. Press Enter/Cancel button to turn on/off air
function. After turning on this function, the air mark shows.
There are 10 types of AIR, but only 1-2 types are for remote control. Refer to the following details:
① 1――The unit continuously runs for 60min, and fresh air valve runs for 6 min.
② 2――The unit continuously runs for 60min, and fresh air valve runs for 12 min.
③ 3――The unit continuously runs for 60min, and fresh air valve runs for 18 min.
④ 4――The unit continuously runs for 60min, and fresh air valve runs for 2 4 min.
⑤ 5――The unit continuously runs for 60min, and fresh air valve runs for 30 min.
⑥ 6――The unit continuously runs for 60min, and fresh air valve runs for 36 min.
⑦ 7――The unit continuously runs for 60min, and fresh air valve runs for 42 min.
⑧ 8――The unit continuously runs for 60min, and fresh air valve runs for 48 min.
⑨ 9――The unit continuously runs for 60min, and fresh air valve runs for 54 min.
⑩ 10――The unit continuously runs for 60min, and fresh air valve always runs.
Turn off air Exchange function: During Air function, press Function button to go to the Air function. In
this case, air mark is blinking, and then press Enter/Cancel button to turn off this function. Air mark will
subsequently disappear.
Air Exchange setting is shown as in Fig.12: