3.2 SWITCHES

Component
CN
(Symbol)
AC (SW1)
282-1,2
(PSU)
Main (SW2)
309-12
(BICU)
Right Vertical
112-2
Guide (SW3)
(IOCSS)
Upper Paper Size
102-1,2,4,5
(SW4)
(IOCSS)
Lower Paper Size
102-6,7,9,10
(SW5)
(IOCSS)
Front Door Safety
120-1,134-3
(SW6)
(IOCSS)

4. BLOWN FUSE CONDITIONS

Fuse
115 V
Power Supply Board
FU1
15 A/125 V
FU2
8 A/125 V
FU4
6.3 A/125 V
FU5
4 A/125 V
FU6
4 A/125 V
SM
Condition
Open
The machine does not turn on.
Shorted
The machine does not turn off.
Open
The LCD does not off when the main switch
is turned off.
Shorted
The LCD does not on when the main switch
is turned on.
Open
The Cover Open indicator is not lit when the
right vertical guide is opened.
Shorted
The Cover Open indicator is lit when the right
vertical guide is closed.
Open
The CPU cannot detect the proper paper
size, and misfeeds may occur when a copy
Shorted
is made.
Open
The CPU cannot detect the proper paper
size, and misfeeds may occur when a copy
Shorted
is made.
Open
The Cover Open indicator is not lit when the
right vertical guide is opened.
Shorted
The Cover Open indicator is lit when the right
vertical guide is closed.
Rating
Symptom when turning on the
220 ~ 240 V
----
No response.
5 A/250 V
No response
6.3 A/125 V/250V "Doors/Covers Open" is displayed
then SC120 is displayed
4 A/125 V/250 V SC900 is displayed
4 A/125 V/250 V Normal operation
(This fuse is on the +24V line of
CN287 but it is not used.)
6-13
Symptom
main switch
(A193)