4800BA(H) - Fucntion settings (SWUSR_1A)
Bit 0: Not used
Bit 1: Dialing type
Bits 2 to 7: Not used
4800BB(H) - PSTN access number from behind PABX (SWUSR_1B)
Access number
Hex value to program (BCD)
0
Ø
0
00
Ø
99
4800C0 to 4800CF(H) - G4 Parameter Switches
(Refer to the ISDN G4 option service manual for details.)
4800D0 to 4800EF(H) - G4 Internal Switches
(Refer to the ISDN G4 option service manual for details.)
4800F0 to 480103(H) - RTI (Max. 20 characters - ASCII) - See the following note.
480104 to 480117(H) - CSI (Max. 20 characters - ASCII)
480118 to 800137(H) - TTI (Max. 32 characters - ASCII) - See the following note.
480138(H) - Number of CSI characters (Hex)
Note: If the number of characters are less than the maximum (20 for RTI, 32 for TTI), add a
stop code (FF[H]) after the last character.
480139 to 480147(H) - Service station's fax number (Service mode 09)
See 48018F(H) for the type of network used for this number.
480157 to 480165(H) - Own fax number (PSTN)
480166 to 480174(H) - Own fax number (ISDN G4)
480175 to 480183(H) - Own fax number (ISDN G3)
480184(H) - ID code (low - Hex)
480185(H) - ID code (high - Hex)
480186(H) - Confidential ID (low - BCD)
480187(H) - Confidential ID (high - BCD)
480188(H) - Memory lock ID (low - Hex)
480189(H) - Memory lock ID (high - Hex)
48018F(H) - Network type used for the service station number
00(H) - G3 (PSTN)
01(H) - G4 (ISDN)
480198 to 48019F(H) - Last power off time (Read only)
480198(H) - 01(H) - 24-hour clock, 00(H) - 12-hour clock (AM), 02(H) - 12-hour clock (PM)
480199(H) - Year (BCD)
48019A(H) - Month (BCD)
48019B(H) - Day (BCD)
48019C(H) - Hour
48019D(H) - Minute
48019E(H) - Second
48019F(H) - 00: Monday, 01: Tuesday, 02: Wednesday, ....... , 06: Sunday
(A639)
0: Pulse dialing (10 pps), 1: Tone (DTMF) dialing
F0
Ø
F0
00
Ø
99
4-71