Gestetner A193 Service Manual page 188

Table of Contents

Advertisement

Rev. 03/99
Mode No.
Class
Class 3
1 and 2
Printer Free
5-901
Run
Test Pattern
Printouts
5-902
LCD Contrast
Adjustment
5-903*
Auto Shut Off
5-904*
Mode Timer
Setting
CSS 25H Off
5-905*
Detection
Fan Control
Timer Setting
5-906*
Brand Name
and
Production
Name Setting
5-907
APS A4/LT
Sideways
Priority
5-911*
PCU Alarm
Interval
1
5-912
PCU Alarm
2
Mode
SM
Function
Performs the printer free run.
To perform the free run, press 1 then
ù
õ
press
twice. Press
Prints the test pattern.
See the "TEST PATTERN PRINTING" Page 4-32 for how
to print a test pattern.
Change to the copy mode display by pressing the
"Interrupt" key, then print out the test pattern.
Adjusts the contrast for the LCD on the
operation panel.
Use the "Zoom" (+ or -) key to change the
contrast. Press clear mode to exit.
Inputs the auto off mode timer.
If "0" is selected, the auto timer function is
disabled.
Japanese version only.
Do not change the value.
Inputs the fan control timer in the energy
saver mode
This time is for entering the fan motor
control mode after the fusing lamp turns
off or the main motor turns off.
Selects the brand name and the
production name for the Plug and Play
function of Windows 95.
The brand name and the production name
for the Plug and Play function is
registered in the NVRAM. If the NVRAM
is defective, these names should be
registered.
Press and hold the "Photo mode" key and
while holding "Photo mode" key then
ù
press the
key to register the setting.
Specifies whether the machine selects LT
sideways paper if the original is A4.
If "Yes" is selected, LT sideways is
selected automatically when the APS
sensors detect an A4 sideways original.
This feature does not work in reverse (A4
sideways paper is not selected for an LT
sideways original).
Inputs the PCU alarm interval.
When the machine reaches the value,
"Change Photoconductor Unit" will be
displayed on the LCD to inform the user.
Selects whether the PCU alarm function
is performed or not.
4-21
SERVICE PROGRAM MODE
Settings
0: No
1: Yes
to stop.
1 ~ 7
1/step
4
0 ~ 120
1 min/step
15
30 ~ 120
1 seconds /
step
30
0: No
1: Yes
1 ~ 255
1 k / Step
45 k
0: No
1: Yes
(A193)