7. 2 Periodic Inspection

Regarding the functions for performing self-diagnosis and monitoring the system status, please
refer to "6.3.5 Maintenance Menu"

7.2.1 Confirming the RX station and Message type

To check the receiving station and message type, please refer to 6.1.3 and 6.3.2. Be sure to set
up the receiving station and message type correctly.

7.2.2 Confirming the Alarm Status

With referring 6.3.5.2, confirm that failure alarm is not occurring. If any alarm occurs, check the
cause of the alarm. NCR-333 Alarm Table is followings.
Failure alarm list (ALR sentence output)
Alarm
Indication
No.
005
Built in self test failure
006
General failure
005
Built in self test failure
051
Antenna malfunction
004
Receiver malfunction
005
Built in self test failure
056
Receiver 1 malfunction
004
Receiver malfunction
005
Built in self test failure
057
Receiver 2 malfunction
004
Receiver malfunction
005
Built in self test failure
058
Receiver 3 malfunction
006
General failure
053
Rx unit modem error
056
Receiver 1 malfunction
053
Rx unit modem error
057
Receiver 2 malfunction
053
Rx unit modem error
058
Receiver 3 malfunction
051
Antenna malfunction
052
Flash memory error
054
Printer error
055
EXT SIO output error
7-2
NCR-333 Alarm Table
Alarm Occurrence Conditions
After carrying out self-diagnosis, NCR-333 detected
that the input voltage was abnormal.
After carrying out self-diagnosis, NCR-333 detected
that the output voltage of antenna terminal was low
voltage.
After carrying out self-diagnosis, NCR-333 detected
that the receiver 1 (518kHz) could not receive
because of abnormalities.
After carrying out self-diagnosis, NCR-333 detected
that the receiver 2 (490kHz) could not receive
because of abnormalities.
After carrying out self-diagnosis, NCR-333 detected
that the receiver 3 (4209.5kHz) could not receive
because of abnormalities.
The input voltage is low level.
The receiver 1 (518kHz) could not receive because
of internal MODEM failure.
The receiver 2 (490kHz) could not receive because
of internal MODEM failure.
The receiver 3 (4209.5kHz) could not receive
because of internal MODEM failure.
The output voltage of antenna terminal is low
voltage.
The flash memory data is abnormal.
External printer is abnormal.
"DISP" output port is abnormal.