Process/Polarity Table; Changing Polarity - Hobart Handler 210 Owner's Manual

Hide thumbs Also See for Handler 210:
Table of Contents

Advertisement

5-4. Process/Polarity Table

Process
GMAW − Solid wire with shield-
ing gas
FCAW − Self-shielding wire −
no shielding gas

5-5. Changing Polarity

Polarity
DCEP − Reverse polarity
DCEN − Straight Polarity
CHANGING
POLARITY
DCEN
Electrode negative for
flux cored wire
1
DCEP
Electrode positive for
solid wire
Cable Connections
Cable To Gun
Connect to positive (+) out-
put terminal
Connect to negative (−)
output terminal
2
Cable To Work
Connect to negative (−) output
terminal
Connect to positive (+) output
terminal
!
Turn off welding power
source.
1
Lead Connections For Direct
Current Electrode Negative
(DCEN)
2
Lead Connections For Direct
Current Electrode Positive
(DCEP)
Always read and follow wire
manufacturer's
recommended
polarity, and see Section 5-4.
Close door.
Ref. 209 228 / Ref. 209 229
OM-227 978 Page 15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents