5-9. Electrical Service Guide

Failure to follow these electrical service guide recommendations could create an electric shock or fire hazard. These recommenda-
tions are for a dedicated branch circuit sized for the rated output and duty cycle of the welding power source.
Input Voltage (V)
Input Amperes (A) At Rated Output
Max Recommended Standard Fuse Rating In Amperes
Min Input Conductor Size In AWG
Max Recommended Input Conductor Length In Feet (Meters)
Min Grounding Conductor Size In AWG
Reference: 2008 National Electrical Code (NEC) (including article 630)
1 If a circuit breaker is used in place of a fuse, choose a circuit breaker with time-current curves comparable to the recommended fuse.
2 "Time-Delay" fuses are UL class "RK5" . See UL 248.
3 "Normal Operating" (general purpose - no intentional delay) fuses are UL class "K5" (up to and including 60 amps), and UL class "H" ( 65 amps and
above).
4 Conductor data in this section specifies conductor size (excluding flexible cord or cable) between the panelboard and the equipment per NEC Table
310.16. If a flexible cord or cable is used, minimum conductor size may increase. See NEC Table 400.5(A) for flexible cord and cable requirements.

5-10. Installing Wire Spool And Adjusting Hub Tension

Installing 8 in. (203 mm) Wire Spool
Tools Needed:
OM-227 978 Page 18
1
2
Time-Delay Fuses
3
Normal Operating Fuses
4
4
Installing 4 in. (102 mm) Wire Spool
Adapter used with
8 in. (203 mm)
spool only.
Retaining ring used
with 8 in. (203 mm)
spool only.
1/2 in.
When a slight force is needed
to turn spool, tension is set.
When a slight force is needed
to turn spool, tension is set.
803 012 / 803 013 -B / Ref. 802 971-C
60 Hz
Single
Phase
230
24
25
35
14
55
(17)
14