5.1

North American 60Hz Power Options

North American Dover Convertible Models (60Hz)
Voltage:
# of Wires:
Frequency:
Current Draw:
Circuit Breaker:
CAUTION (For 4-wire, 240 VAC Heater Operation): Move the red wire on
the main terminal strip (TB1) from position #1 to position #3. Make certain
wires are connected exactly as shown in Figure D (page 15) before apply-
ing power. Failure to do so will result in damage to the circuit board and/or
related components and void the manufacturer's warranty.
* In the 15A and 30A configuration, the heater will not operate at the same
time as the high-speed jets pump. The factory setting is 120V/15A.
Note: all Canadian spas must be hard wired (120 VAC or 240 VAC)
per CSA Canadian standards (page 4).
** If the spa is to be operated on 40A service, remove the jumper JP1 #1-2
on the circuit board to allow the heater to operate at the same time as the
high-speed jets pump (page 41)
North American 1-Pump Camden Model (60Hz)
Voltage:
# of Wires:
Frequency:
Current Draw:
Circuit Breaker:
* In the 40A configuration, the heater will not operate while the jets pump
is running in high speed.
** In the 50A configuration, the heater will operate while the jets pump is
running in high speed. This is the factory setting.
Page 10
120V/15A*
120 VAC
3 (15A GFCI
Cord, US Models
Only*)
60Hz
12A
15A*, 1-Pole
240V/40A*
240 VAC
3
60Hz
26A
40A*, 2-Pole
240V/30A*
240 VAC
4 (Hard Wired
Only)
60Hz
21A
30A*, 2-Pole
240V/50A**
240 VAC
50A**, 2-Pole
240V/40A**
240 VAC
4 (Hard Wired
Only)
60Hz
30A
40A**, 2-Pole
3
60Hz
36A