Us/Canada 60Hz Power Options - Sundance Spas Camden Owner's Manual

780 series
Table of Contents

Advertisement

5.1 US/Canada 60Hz Power Options

US/Canada Metro Convertible Models (60Hz)
Voltage:
# of Wires:
Frequency:
Current Draw:
Circuit Breaker:
For 240 VAC Heater Operation: Move the red wire on the main terminal
strip (TB1) from position #1 to position #3. Make certain wires are connected
exactly as shown in Figure-D (
do so will result in damage to the circuit board and/or related components
and void the manufacturer's warranty.
*
In the 15A and 30A configuration, the heater will not operate at the same
time as the high-speed jets pump. The factory setting is 120V/15A.
Note: all Canadian spas must be hard wired (120 VAC or 240 VAC)
per CSA Canadian standards.
** If the spa is to be operated on 40A service, remove the jumper JP1 #1-2
on the circuit board to allow the heater to operate at the same time as the
high-speed jets pump (
US/Canada 1-Pump Camden Model (60Hz)
Voltage:
# of Wires:
Frequency:
Current Draw:
Circuit Breaker:
* In the 40A configuration, the heater will not operate at the same time as
the high-speed jets pump.
** In the 50A configuration, the heater will operate at the same time as the
high-speed jets pump. This is the factory setting.
Page 10
120V/15A*
120 VAC
3 (15A GFCI Cord,
US Models Only*)
60Hz
12A
15A, 1-Pole
page 14
page 42
240V/40A*
240 VAC
3
60Hz
26A
40A, 2-Pole
240V/30A*
240 VAC
4 (Hard
Wired Only)
60Hz
21A
30A, 2-Pole
) before applying power. Failure to
).
240V/50A**
240 VAC
3
60Hz
36A
50A, 2-Pole
240V/40A**
240 VAC
4 (Hard
Wired Only)
60Hz
30A
40A, 2-Pole