Fisher & Paykel CG302D Installation Instructions Manual page 11

Gas-on-glass cooktop
Hide thumbs Also See for CG302D:
Table of Contents

Advertisement

11
FIT CLAMPING BRACKETS BASED ON THE
BENCHTOP THICKNESS
x 4
view from below
16-20mm
20-30mm
13
CONNECT TO GAS SUPPLY
NG Models
Make sure to fit the supplied
regulator.
Adjust to obtain a test point
pressure of 1 kPa with all
Arrow
burners operating at
highest setting.
ALL Models
Make sure the connection point will be accessible with the cooktop installed.
To enable the gas supply to be readily shut off by the customer, make sure the connection
is fitted with an isolating valve close to the cooktop.
If connecting the gas with a flexible hose:
Ensure the hose is long enough to allow for removal of cooktop for servicing.
Make sure the connector is located as shown in step 5 CLEARANCE DIMENSIONS.
The hose assembly must be AS/NZS 1869 Class B or D certified, with an Rp ½" (ISO 7‐1) female thread connection.
The hose assembly must be no longer than 1.2 m in length with minimum internal
diameter of 10 mm and comply with relevant AS 5601/NZS 5261 requirements.
The hose must not be kinked, subjected to abrasion or permanently deformed.
The hose must not be near or in contact with any hot surfaces
(e.g. base of metal hotlplate, flue, or chassis of underbench oven etc.)
30-40mm
LPG Models
Make sure to fit the supplied
test point adaptor.
Make sure the supply pressure
is regulated to 2.75 kPa, with all
burners operating at highest
setting.
12
SECURE TO BENCHTOP
40mm+
14
CHECK ALL CONNECTIONS FOR GAS LEAKS
GAS
GAS
ON
ON
x 4
Repeat on all the other sides
11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cg451dCg603dCg604dCg752dCg903dCg905d

Table of Contents