When The Louver Does Not Operate - Heat Controller B-MMC09FA-1 Service Manual

Wall mounted multi-split system air conditioning/heat pump
Hide thumbs Also See for B-MMC09FA-1:
Table of Contents

Advertisement

Troubleshooting Guide

When the louver does not operate.

Trouble 5
When Vertical Louver does not operate.
• Confirm that the Vertical Louver is normally geared with the shaft of
Stepping Motor.
• If the regular torque is detected when rotating the Vertical Louver with
hands
• Check the connecting condition of CN-UP/DOWN Connector
• Check the soldering condition(on PWB) of CN-UP/DOWN Connector
• Confirm that there is DC + 12V between pin (RED) of CN-UP/DOWN and
GND.
• Confirm that there is a soldering short at following terminals.
- Between
- Between
- Between
- Between
• Confirm the assembly conditions that are catching and interfering parts in
the rotation radial of the Vertical Louver
70 Multi type Air Conditioner
Normal
Check the operating circuit of the Vertical Louver
,
,
and
of MICOM
60
61
62
63
,
,
and
of IC01M
2
3
4
5
,
,
,
of IC01M
12
13
14
15
,
,
,
and
of CN-UP/DOWN
1
2
3
4
5
If there are no problems after above checks

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents