Product Specifications
Outdoor Unit - Multiple piping models
Model
Cooling Capacity#
Heating Capacity#
Input#
Cooling
Heating
Running Current#(208/230V)
Cooling
Heating
Power Supply
Max. Number of Connectable Indoor Units
Compressor
Type
(Constant)
Model
Motor Type
Quantity
Motor Input
Oil Charge
Oil Type
Capacitor
O.L.P Type(model name)
Compressor
Type
(Constant)
Model
Motor Type
Quantity
Motor Input
Oil Charge
Oil Type
Capacitor
O.L.P Type(model name)
Refrigerant charge
Charge
Type
Control
Coil
Tube Size (OD)
Fins per inch
No. of Rows & Column/No.
Fan motor
Model
Output
Capacitor
Fan
Type
No. Used / Diameter
Discharge
Air Circulation
Outdoor
Noise Level(H/L) at 230V
Sound Press,1m
Defrosting
SVC Valve
Liquid
Gas
Dimensions
W*H*D
Net Weight
Outdoor
Max. Interunit Piping Length
Total of Each Room
For One Room
Max. Installation
Indoor Unit~Outdoor Unit
Height Difference
Indoor Unit~Indoor Unit
Packing Dimension
W*H*D
Testing Combinations
Stuffing Quantity
Note:
1. Capacities are based on the following conditions:
Cooling:
- Indoor Temperature 26.7˚C(80˚F) DB/19.4˚C(67˚F) WB
- Outdoor Temperature 35˚C(95˚F) DB/23.9˚C(75˚F) WB
Heating:
- Indoor Temperature 21.1˚C(70˚F) DB/15.6˚C(60˚F) WB
- Outdoor Temperature 8.3˚C(47˚F) DB/6.1˚C(43˚F) WB
Piping Length
- Interconnecting Piping Length 7.5m
- Level Difference of Zero
16 Multi type Air Conditioner
Btu/hr
W
kcal/hr
Btu/hr
W
kcal/hr
W
W
A
A
Ø,V,Hz
Ea
W
cc
µF/Vac
Ea
W
cc
µF/Vac
g(oz)
inch(mm)
W
µF/Vac
EA/inch(mm)
Side / Top
CMM(CFM)
dB(A) 1
inch(mm)
inch(mm)
kg(lbs)
m
m
m
m
inch(mm)
20/40ft
A-MMH18FA-1
9,000~18,000
2637~5275
2267~4536
9,000~18,000
2637~5275
2267~4536
1070~1980
1040~1960
4.9~8.8
4.6~8.6
1,208/230,60
2
Rotary
GK094K
Hermetic
1
955
330±10
FVC68D
30 / 370
External Type(MRA98996-12026)
Rotary
GK113K
Hermetic
1
1,120
330±10
FVC68D
35 / 370
External Type(MRA12124-12026)
1400(49)
R410A
EEV
0.276(7.0)
18
2R,28C
IC-1640LG GE
90
6/370
Propeller
1 / 460
Side
50(1765.7)
51
Invertion Cycle
1/4 (6.35) * 2EA
3/8 (9.52) * 2EA
34.3*25.8*12.6 (870*655*320)
57(125.7)
30
15
7.5
7.5
40.2*28.2*17.2 (1020*716*437)
S4 9k + S4 9k
81/171
2. Wiring cable size must comply with the applicable local and national code.
3. Capacities are Net Capacities.
4. #: See the page "Combination Table"
5. The specification may be subject to change without prior notice for purpose
of improvement.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents