Heat Controller B-MMC09FA-1 Service Manual page 27

Wall mounted multi-split system air conditioning/heat pump
Hide thumbs Also See for B-MMC09FA-1:
Table of Contents

Advertisement

Wrap the insulation material around the connecting por-
tion.
1. Overlap the connection pipe heat insulation and the indoor
unit pipe heat insulation material. Bind them together with
vinyl tape so that there may be no gap.
2. Wrap the area which accommodates the rear piping hous-
ing section with vinyl tape.
3. Bundle the piping and drain hose together by wrapping
them with cloth tape over the range within which they fit
into the rear piping housing section.
Reroute the pipings and the drain hose across the back
of the chassis.
Indoor unit installation
1. Remove the spacer.
2. Ensure that the hooks are properly seated on the installa-
tion plate by moving it left and right.
3. Press the lower left and right sides of the unit against the
installation plate until the hooks engage into their
slots(clicking sound).
Flaring Work and Connection of Piping
Plastic bands Insulation material
Connection
pipe
Vinyl tape
Wrap with vinyl tape
(wide)
Pipe
Vinyl tape(narrow)
Connecting cable
Pipe
Drain hose
Vinyl tape(narrow)
Wrap with
vinyl tape(wide)
Piping for
passage through
piping hole
Service Manual 27
Indoor
unit piping
Connecting
cable
Drain hose

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents