Chapter 6 Specifications
(3) Common specifications of 200 V class and 400 V class models (continued)
Model name (type
055
name)
SJ700B-XXXF/FF/FUF
Vibration
tolerance
(See Note 6)
Installation
environment
Coating color
Internal option
Parts lifespan
Feedback option
Digital input option
DeviceNet option
LonWorks option
Profibus-DP option
Other optional
Braking resistor, AC reactor, DC reactor, noise filter, operator cables, Harmonic-wave suppressor unit, LCR
components
filter, analog operation panel, regenerative braking unit, controllers for various applications
Note 1: The vibration tolerance was tested in compliance with JIS
Note 2: The insulation distance complies with the UL and CE standards.
Note 3: The applicable motor refers to Hitachi standard 3-phase motor(4-pole).when using other motors,care must be taken to
prevent the rated motor current(50/60Hz)from exceeding the rated output current of the inverter.
Note 4: Function "64(EMR)"cannot be assigned to input terminal 3 by an operation from the operator. The function is automatically
assigned to the terminal when slide switch SW1 is set to ON.
Note 5: The storage temperature refers to the short-term temperature during transport.
Note 6: The frequency command will equal the maximum frequency at 9.8V for input voltage 0 to 10VDC,or at 19.8mA for input
current 4 to 20mA.If this characteristic is not satisfactory for your application, contact your Hitachi sales representative.
Note 7: The analog voltage monitor and the analog current monitor are rough output values for analog meter connection.
The maximum output value might shift a little by the difference of the analog output circuit than 10V or 20mA.
Please inquire when there is a possibility that the inconvenience is caused.
Note8: As for the range of the speed change, the variation range is different according to the installation situation and the
characteristic and the usage condition of the motor. Please inquire about details.
Note9: The density of air decreases by 1% whenever rising by 100m when the altitude exceeds 1000m. Therefore, it is necessary to
decrease the calorific value. The calorific value of the main circuit semiconductor such as IGBT is proportional to the current
and the voltage. Therefore, please decrease by 1% and use the current rating every time it rises by 100m.
Please inquire about use in the high ground of 2500m or more.
Note10: When Sensor-less vector control is selected (A044=03), you may not obtain an intended starting torque or motor may trip
depending on the applied motor.
Note11: The inverter detects IGBT error (E30) as a protection function.
However IGBT error (E30) is not a protection for an output short circuit, therefore there is a possibility that IGBT will get
damaged.
Moreover overcurrent error (E01 to E04) may be detected instead of IGBT error depending on the operational condition of an
inverter.
075
110
150
H
H
L/H
L/H
2
5.9m/s
(0.6G),10~55Hz
Environment without corrosive gases and dust, at an altitude of 1,000 m or less (Note 7)
Smoothing capacitor : 10 years (designed lifespan)
Option to support the open-network DeviceNet function
Option to support the open-network LonWorks function
Option to support the open-network Profibus-DP function
185
220
300
370
L/H
L/H
L/H
L/H
Gray
Zero-phase reactor,EMI filter (Class C3)
Cooling fan : 10 years (designed lifespan)
Vector control with sensor
4-digit BCD input, 16-bit binary input
C60068-2-6:2010 (IEC 60068-2-6:2007).
6 - 4
450
550
750
900
L/H
L/H
L/H
H
2
2.94m/s
(0.3G),10~55Hz
1100
1320
1600
H
H
H