Hitachi SJ700B SERIES Quick Reference Manual page 56

Inverter
Hide thumbs Also See for SJ700B SERIES:
Table of Contents

Advertisement

Code
Function name
C111
Overload setting (2)
C121
[O] input zero calibration
C122
[OI] input zero calibration
C123
[O2] input zero calibration
C130
Output 11 on-delay time
C131
Output 11 off-delay time
C132
Output 12 on-delay time
C133
Output 12 off-delay time
C134
Output 13 on-delay time
C135
Output 13 off-delay time
C136
Output 14 on-delay time
C137
Output 14 off-delay time
C138
Output 15 on-delay time
C139
Output 15 off-delay time
C140
Output RY on-delay time
C141
Output RY off-delay time
C142
Logical output signal 1 selection 1
C143
Logical output signal 1 selection 2
Logical output signal 1 operator
C144
selection
C145
Logical output signal 2 selection 1
C146
Logical output signal 2 selection 2
Logical output signal 2 operator
C147
selection
C148
Logical output signal 3 selection 1
C149
Logical output signal 3 selection 2
Logical output signal 3 operator
C150
selection
C151
Logical output signal 4 selection 1
C152
Logical output signal 4 selection 2
Logical output signal 4 operator
C153
selection
C154
Logical output signal 5 selection 1
C155
Logical output signal 5 selection 2
Logical output signal 5 operator
C156
selection
C157
Logical output signal 6 selection 1
C158
Logical output signal 6 selection 2
Logical output signal 6 operator
C159
selection
C160
Input terminal response time setting 1
C161
Input terminal response time setting 2
C162
Input terminal response time setting 3
C163
Input terminal response time setting 4
C164
Input terminal response time setting 5
C165
Input terminal response time setting 6
C166
Input terminal response time setting 7
C167
Input terminal response time setting 8
Input terminal response time setting
C168
FW
Multistage speed/position
C169
determination time
Monitored data or setting
0.00 to 1.50 x "rated current" (A)
0. to 9999., 1000 to 6553 (10000 to 65530)
0. to 9999., 1000 to 6553 (10000 to 65530)
0. to 9999., 1000 to 6553 (10000 to 65530)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
Same as the settings of C021 to C026 (except those of LOG1 to
LOG6)
Same as the settings of C021 to C026 (except those of LOG1 to
LOG6)
00 (AND), 01 (OR), 02 (XOR)
Same as the settings of C021 to C026 (except those of LOG1 to
LOG6)
Same as the settings of C021 to C026 (except those of LOG1 to
LOG6)
00 (AND), 01 (OR), 02 (XOR)
Same as the settings of C021 to C026 (except those of LOG1 to
LOG6)
Same as the settings of C021 to C026 (except those of LOG1 to
LOG6)
00 (AND), 01 (OR), 02 (XOR)
Same as the settings of C021 to C026 (except those of LOG1 to
LOG6)
Same as the settings of C021 to C026 (except those of LOG1 to
LOG6)
00 (AND), 01 (OR), 02 (XOR)
Same as the settings of C021 to C026 (except those of LOG1 to
LOG6)
Same as the settings of C021 to C026 (except those of LOG1 to
LOG6)
00 (AND), 01 (OR), 02 (XOR)
Same as the settings of C021 to C026 (except those of LOG1 to
LOG6)
Same as the settings of C021 to C026 (except those of LOG1 to
LOG6)
00 (AND), 01 (OR), 02 (XOR)
0. to 200. (
2ms)
0. to 200. (
2ms)
0. to 200. (
2ms)
0. to 200. (
2ms)
0. to 200. (
2ms)
0. to 200. (
2ms)
0. to 200. (
2ms)
0. to 200. (
2ms)
0. to 200. (
2ms)
0. to 200. (
10ms)
4 - 13
Chapter 4 List of Data Settings
Default
_F/_FF
_FUF
Rated current of inverter
Factory setting
Factory setting
Factory setting
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
1
1
1
1
1
1
1
1
1
0
Setting
Change
during
during
operation
operation
(allowed or
(allowed or
not)
not)