AGFA Rapiline 51 User Manual page 19

Film processor
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
- do the replenishment pumps work properly?
Check this by activating the replenishment
key
a few times, and check that all air has been
expelled from the pumps and hose connec-
tions to the developer and fixer tanks.
Start the processor by activating the sensors
in the insertion slot.
5) Set the required temperature in the
developer, fixer, and dryer sections. Let the
processor run for half an hour.
6) Switch off the processor - let the water out
of the tanks and the replenishment
containers. You should empty each tank
separately to avoid overflow in the floor
drain.
Fill the tanks with the proper chemical
solutions according to the mixing instructions
provided by the chemistry manufacturers.
First, fill the fixer (if any fixer is spilled into the
developer tank - rinse thoroughly with water),
and then the developer. It is important to fill
the tanks fully up to the overflow - if not, the
film may be stained.
7) Fill the replenishment containers with
Adjustments of the processor´s electrical processes must only be made by a qualified service technician.
1
18.01.96
replenisher for developer and fixer.
According to the mixing instructions.
8) Switch on the processor. Set the
required developing time. Run some
cleaning film through the processor and
check the film transport.
9) Open the valve for rinsing water.
The rinsing water will run when the
sensors on the insertion table is activated.
User Manual
Page 15/16/GB

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents