CHECKING PRESET VALUES
You can check any preset value at any time
in the proceedings.
Example: You want to check the actual fixer
temperature and the required temperature
as preset on the control panel. Follow these
steps in sequence:
Press
"FIX TEMP
33
0
displayed for approximately 10 sec.)
Press
"FIX SET 35
C" (previously set tempera-
0
ture, displayed for approximately 10 sec.).
If the previously set temperature is accepta
ble, press
If the previously set temperature is not ac
ceptable, press
until reaching the required temperature.
Press
when reaching the required
User manual
Page 10/16/GB 
C" (actual temperature,
or
temperature.
ADJUSTING THE DEVELOPER TIME
(EXAMPLE)
A developer time of 20 seconds is required.
The present setting is 16 seconds. To alter
this setting, follow these steps in sequence:
Press
"DEV TIME 16 sec"
Press
"DEV SET 16 sec"
Press
"DEV SET 20 sec"
Press
18.01.96