TROUBLESHOOTING PROCEDURE - ELECTRONIC IGNITION SYSTEM
START
• Turn Off Gas Supply.
• Ensure Valve Switch Is In ON Position.
• Disconnect Control Harness.
• Set Thermostat To Call For Heat.
Insert A
End View of Control Harness Connector
2 Volt
2 Volt Hot
Common
2 Volt
Switched
Check For Damaged or Missing
Terminals in Connector
Insert B
Igniter Terminals
Igniter will cycle off and
1
back on once during the 90
second ignition trial. All
voltage measurements must
be taken while the igniter is
powered.
• Check for proper volt-
age at control harness
(see insert A). Voltage
NO
2
should be 2V between
thermostat or pressure
switch and 2V common
and 2V hot.
YES
• Plug control harness into
valve. Wait for internal check
delay.
NO
• Igniter warms up and glows
red.
YES
1
NO
• Turn on gas supply.
• Pilot burner lights.
YES
• Main valve opens and main
NO
burner lights.
YES
• System Is okay.
When measuring voltage
2
at connections, use care
to ensure terminals are
not damaged.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
CHECK
• Line voltage power
• Low voltage transformer
• Limit controller
• Thermostat
• Wiring
• With pilot burner cable con-
1
nected, measure voltage at
valve HSI element output. 2V
2
nominal. (See insert B)
YES
• Replace igniter/flame rod
assembly.
YES
• Check that pilot gas is flowing. Wait
to ensure pilot gas tubing is purged.
Recycle call for heat if necessary.
YES
• Measure voltage between 2V hot and
2V common leads to valve control.
Must measure at least 19.5 VAC with
igniter powered (see insert A). To
identify proper lead, this check must
be done with the valve control con-
nected and igniter powered.
YES
• Replace Pilot Assembly.
• Check that pilot flame makes good
contact with pilot burner flame rod.
• Check for good electrical connection
through the pilot tubing.
• If both of the above are good, replace
igniter/flame rod assembly.
YES
• Cycle thermostat off and back on.
• Main burner lights.
NO
• Replace valve.
NO
• Replace valve.
• Check transformer and
NO
line volt supply.
NO
• Replace valve.