WARNING
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN TO
TOUCH GLASS.
WARNING: If the information in these instructions is
not followed exactly, a fire or explosion may result
causing property damage, personal injury or death.
- Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
- Installation and service must be performed by a quali-
fied installer, service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
INSTALLATEUR: Laissez cette notice avec l'appareil.
CONSOMMATEUR: Conservez cette notice pour consul-
tation ultérieure.
OTL Report No. 116-F-32-5
CARE AND OPERATION INSTRUCTIONS
Direct-Vent
MODELS
Millivolt Models
SSDVST-CNM-B
SSDVPF-CNM-B
AVERTISSEMENT
UNE SURFACE VITRÉE CHAUDE PEUT
NE PERMETTEZ JAMAIS À UN ENFANT
DE TOUCHER LA SURFACE VITRÉE.
AVERTISSEMENT: Assurez-vous de bien suivre les
instructions données dans cette notice pour réduire
au minimum le risque d'incindie ou d'explosion ou
pour éviter tout dommage matériel, toute blessure
ou la mort.
- Ne pas entreposer ni utilizer d'essence ni d'autres
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir
des téléphones se trouvant dans le bâtiment où vous
trouvez.
• Appelez immédiatement votre fournisseur de gaz
depuis un voisin. Suivez les instructions du fournis-
seur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
- L'installation et l'entretien doivent être assurés par un
installateur ou un service d'entretien qualifié ou par
le fournisseur de gaz.
Electronic Models
SSDVST-CNE-B
SSDVPF-CNE-B
CAUSER DES BRÛLURES.
LAISSER REFROIDIR LA SURFACE
VITRÉE AVANT D'Y TOUCHER.

Advertisement

Table of Contents
loading

Summary of Contents for Superior SSDVST-CNM-B

  • Page 1 CARE AND OPERATION INSTRUCTIONS Direct-Vent P/N 725,035M REV. E 03/2010 MODELS Portland OTL Report No. 116-F-32-5 Millivolt Models Electronic Models SSDVST-CNM-B SSDVST-CNE-B SSDVPF-CNM-B SSDVPF-CNE-B Ce manuel d’installation est disponible en francais, simplement en faire la demande. Numéro de la pièce 725,035CF AVERTISSEMENT WARNING UNE SURFACE VITRÉE CHAUDE PEUT...
  • Page 2: Table Of Contents

    CONGRATULATIONS! GENERAL INFORMATION In selecting this Superior direct-vent gas appliance you have chosen the finest and most WARNING dependable fireplace to be found anywhere. It's a beautiful, prestigious alternative to a wood burning fireplace. Welcome to a family of tens of thousands of satisfied Superior...
  • Page 3 Note: Installation and repair should be Due to high temperatures the appliance WARNING done by a qualified service person. The should be located out of traffic and away from furniture and draperies. Locate appliance should be inspected before use Failure to comply with the instal- furniture and window coverings accord- and at least annually by a professional lation and operating instructions...
  • Page 4 Test gauge connections are provided on the Millivolt Models - BTU Input Burner Orifice Sizes front of the millivolt gas control valve, identi- Elevation 0-500 feet ( 0-1372 meters) Millivolt models come standard with the manu- fied IN for the inlet and OUT for the manifold ally-modulated gas valve;...
  • Page 5: Operation / Care Of Your Appliance

    OPERATION AND CARE OF YOUR APPLIANCE On millivolt systems, the piezo igniter, HI/LO flame adjustment knob, and pilot and main gas OFF/PILOT/ON control knob are located below WARNING the glass panel enclosure. The gas valve for electronic systems is also located below the Young children should be carefully supervised when they are in the glass enclosure panel.
  • Page 6: Variable Flame Adjustment

    Variable Flame Height Adjustment Electronic Appliances - (Millivolt Appliances only) HI/LO Variable To light electronic appliances refer to detailed Inlet Pressure Tap Flame Height lighting instructions found on Pages 19 and All Millivolt appliances are equipped with a Adjustment Manifold Pressure Tap 20.
  • Page 7: Attaching Safety In Operation Warnings

    HOMEOWNER’S INSTRUCTIONS - ATTACHING SAFETY IN OPERATION WARNINGS ATTACHING SAFETY IN OPERATION WARN- APPOSITION DES MISES EN GARDE RELATIVES COLOCACIóN DE ADVERTENCIAS DE SEGURIDAD INGS À LA SÉCURITÉ D’UTILISATION EN OPERACIóN Your fireplace has been furnished with safety instruc- Votre foyer a été livré avec des étiquettes de sécurité qui Su chimenea incluye etiquetas de instrucciones tion labels that are to be affixed to the operation and doivent être collées à...
  • Page 8: Maintenance

    MAINTENANCE Replacing Logs Note: Clean glass after first two weeks of opera- tion (after Burn-In period is over) and then only If the logs become damaged by accident or (See Maintenance Schedule, Page 21) when necessary and when the fireplace is cool. improper handling and need replacement, Wipe surface with clean, dampened, soft cloth.
  • Page 9: Front Glass Enclosure Panel, Removal And Installation

    Front Glass Enclosure Panel, Removal Only doors certified with the appliance Top Flange on and Installation shall be used. Glass Door Glass Door Seules des portes certifiées pour cet WARNING appareil doivent être utilisées. • Do not attempt to substitute the CAUTION: DO NOT abuse glass door by materials used on this door, striking or slamming shut.
  • Page 10 BURNER POSITIONING Install the unitized log set: WARNINGS NOTE: INSTALL REAR BURNER FIRST, THEN FRONT BURNER. a. The bottom of the log set is notched to ac- BURNER • This appliance is not designed BRACKET A PORTS commodate the pilot. REAR BURNER to burn wood.
  • Page 11 BURNER ADJUSTMENTS (QUALIFIED TECHNICIANS ONLY) Flame Appearance and Sooting Proper flame appearance is a flame which is blue at the base and becomes yellowish-orange in the body of the flame. When the appliance is first lit, the entire flame may be blue and will gradually turn yellowish-orange during the first 15 minutes of operation.
  • Page 12: Burner Flame Appearance & Sooting Page 11 Burner Air Shutter Adjustments

    Burner Air Shutter Adjustment Procedure Air Shutter Adjusting ***Main Burner Factory Air Shutter Burner Air Shutter WARNINGS Opening Setting - All Models Venturi Opening Tube Natural Gas Propane Gas • Air shutter adjustment should inches (mm) inches (mm) only be performed by a quali- Orifice * TWO 1/8 (3) Slots ** TWO 11/16 (17) Slots fied professional service...
  • Page 13: Warranty

    Normally, all parts should be ordered through WARRANTY your LHP distributor or dealer. Parts will be 1508 Elm Hill Pike, Suite 108 shipped at prevailing prices at time of order. Nashville, TN 37210 Your gas appliance is covered by a limited twenty visit us at www.Lennox.com year warranty.
  • Page 14: Accessory Components

    ACCESSORY COMPONENTS PRODUCT REFERENCE INFORMATION Cat. Model Ship Ship. Volume H3335 SSDVPF-CNM 270 lbs 52W x 27D x 44 1/2H (36.2 cu.ft). H3336 SSDVPF-CNE 270 lbs 52W x 27D x 44 1/2H (36.2 cu.ft). H3333 SSDVST-CNM 282 lbs 52W x 27D x 44 1/2H (36.2 cu.ft).
  • Page 15 *H1527 LK-600BS 0" (ref. Form # 750,166M) Forced Air Blower Kits * Superior Nameplate Logo, 56L93, is not included. Cat. Model No. Description Polished Brass and Brushed Stainless Louvers Kits These kits include a top 4-louver assembly and a bottom 4-louver assembly. They provide a touch of elegance.
  • Page 16 ACCESSORY COMPONENTS (CONTINUED) Arch Door Kit - Polished Brass Cat. No. Model Where Used 80L95 ADKE-60B 2" 80L93 ADK-6/60B 0" Arch Door Kit - Brushed Stainless Steel Cat. No. Model Where Used 81L05 ADKE-60P 2" 3 Piece Trim Kit (SSDVST only) 81L03 ADK-6/60P 0"...
  • Page 17: Lighting Instructions - Millivolt

    LIGHTING INSTRUCTIONS – MILLIVOLT GAS VALVE FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. A. This appliance has a pilot which must be lit with a piezo •...
  • Page 18 INSTRUCTIONS D’ALLUMAGE – VANNE GAZ MILLIVOLT POUR PLUS DE SÉCURITÉ, LIRE AVANT D’ALLUMER AVERTISSEMENT. QUICONQUE NE RESPECTE PAS À LA LETTRE LES INSTRUCTIONS DANS LA PRÉSENTE NOTICE RISQUE DE DÉCLENCHER UN INCENDIE OU UNE EXPLOSION ENTRAÎNANT DES DOMMAGES, DES BLESSURES OU LA MORT. •...
  • Page 19: Lighting Instructions - Electronic

    OPERATING INSTRUCTIONS — ELECTRONIC FOR YOUR SAFETY READ BEFORE OPERATING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. A. This appliance is equipped with an ignition device which •...
  • Page 20 INSTRUCTIONS D’ALLUMAGE — ELECTRONIC POUR PLUS DE SÉCURITÉ LIRE AVANT DE METTRE EN MARCHE AVERTISSEMENT: SI VOUS NE SUIVEZ PAS CES INSTRUCTIONS À LA LETTRE, IL POURRAIT S’EN SUIVRE UN INCENDIE OU UNE EXPLOSION CAUSANT DES DOMMAGES MATÉRIELS, DES BLESSURES CORPORELLES OU MÊME DES PERTES DE VIE. A.
  • Page 21: Maintenance Schedule

    MAINTENANCE SCHEDULE Turn off gas and electrical power to the fireplace and allow it to cool before cleaning or servicing the appliance. Annually (Before the onset of the Burning Season) MAINTENANCE TASK ACCOMPLISHING PERSON PROCEDURE Inspect/Clean Burner, Logs Qualified Service Technician Inspect valve and ensure it is properly operating.
  • Page 22: Troubleshooting Guide - Millivolt

    TROUBLESHOOTING THE MILLIVOLT CONTROL SYSTEM Note: Before troubleshooting the gas control system, Ensure external gas shut off valve, located at gas supply inlet, (and wall switch, iff applicable), is in the “ON” position. Important: Valve system troubleshooting should only be accomplished by a qualified service technician. SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION...
  • Page 23 TROUBLESHOOTING PROCEDURE - ELECTRONIC IGNITION SYSTEM START CHECK • Turn Off Gas Supply. • Check for proper volt- • Line voltage power age at control harness • Ensure Valve Switch Is In ON Position. • Low voltage transformer (see insert A). Voltage •...
  • Page 24: Replacement Parts List

    All NG Models 93L32 Flex Gas Line Connector, FFGC All Models (.086”) * Superior Nameplate Logo, 56L93, is sold separately. 19L52 Orifice, Propane, #55 (.052”) All LP Models Contact an Authorized LHP dealer to obtain any of these parts. Never WARNING use substitute materials.
  • Page 25 REPLACEMENT PARTS DIAGRAMS Cabinet Firebox Note: Cabinet and Firebox shown for reference only. NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
  • Page 26 NOTES:...
  • Page 27 NOTES: NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
  • Page 28 LHP reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information. Printed in U.S.A. © 2005 by LHP P/N 725,035M REV.