Technical Data - Carrier 40KMC---N Installation Manual

Split system global cassette indoor unit
Hide thumbs Also See for 40KMC---N:
Table of Contents

Advertisement

40KMC---N

Technical data

Table I: Nominal data
POWER INPUT (WATT)
Cooling only
standard
Sizes
12
40KMC012-7N
18
40KMC018-7N
24
40KMC024-7N
28
40KMC028-7N
36
40KMC036-7N
48
40KMC048-7N
60
40KMC060-7N
Sizes
with electric heaters
12
40KMC112-7EN
18
40KMC118-7EN
24
40KMC124-7EN
28
40KMC328-7EN
36
40KMC336-7EN
48
40KMC348-7EN
60
40KMC360-7EN
Note: For power supply wire size and delay type fuses, refer to the outdoor unit installation instructions.
Table II: Technical data of electric heaters (if installed)
Mod.
Electric heater
capacity
Supply voltage
Max. current draw
Control device
Safety thermostat
Power supply cables
Recommended fuse (gL type)
*In areas with a 2 kW limit for single-phase electric heaters it is possible to divide the power supply on two phases and neutral of a three phase supply with neutral.
Use cable type H07 RN-F - 4G1,5 mm
Table III:
Material supplied
Table IV: Operating limits
Cooling / Heating
Main power supply
Electric heater
Table V: Components required for a complete installation
Name
Connection pipe
Wall sleeve
Wall cap
Finishing tape
Fastening tape
Tube insulation
Drain hose
Sealer putty
- Outdoor power supply cable
- Electrical connecting cable
between indoor and outdoor unit
Cooling
Heating
75
75
80
80
105
105
107
107
131
131
178
178
231
231
Cooling
Heating
75
1575
80
2580
105
2605
107
3107
131
3131
178
3178
231
3231
Heat pump
12
18
24
kW
1.5
1.5
1.5
2 x 1.0 2 x 1.0 2 x 1.0 2 x 1.0
V
230
230
230
A
6.5
6.5
6.5
N° 1 Manual reset thermostat ST1 60°C
N° 1 Manual reset thermostat ST2 100°C
2
mm
3 G 1.5 3 G 1.5 3 G 1.5 4 G 1.5 4 G 1.5 4 G 1.5 4 G 1.5 3 G 1.5 3 G 2.5 3 G 2.5 5 G 1.5 5 G 1.5 5 G 1.5 5 G 1.5
A
8
8
8
2
- 400V 2N ~
Description
Installation instructions
Owner's Manual
Fresh air intake baffle
Refer to outdoor unit installation manual.
Nominal single-phase voltage
Operating voltage limits
Nominal three-phase voltage
Operating voltage limits
°
27
C
40KMC 012N Ø (1/2") 12.70 mm (Gas) / Ø (1/4") 6.35 mm (Liquid)
40KMC 018N, 024N, 028N, 036N, 048N and 060N Ø (1/2") 12.70 mm (Gas) / Ø (1/4") 6.35 mm (Liquid)
PVC film
I.D. 16 - 17 mm
H07 RN-F (60245IEC66),
cable with synthetic rubber insulation and polychloroprene sheath.
H07 RN-F (60245IEC66),
cable with synthetic rubber insulation and polychloroprenesheath.
standard
Sizes
12
40KMC012-7N
18
40KMC018-7N
24
40KMC024-7N
28
40KMC028-7N
36
40KMC036-7N
48
40KMC048-7N
60
40KMC060-7N
Sizes
with electric heaters
12
40KMC112-7EN
18
40KMC118-7EN
24
40KMC124-7EN
28
40KMC328-7EN
36
40KMC336-7EN
48
40KMC348-7EN
60
40KMC360-7EN
28
36
48
60
230
230
230
230
(*)
(*)
(*)
(*)
8.8
8.8
8.8
8.8
GMC electronic control
8
8
8
8
230V ~ 50Hz
min. 198V – max. 264V
400V 3N ~ 50Hz
min. 342V – max. 462V
Specification
POWER INPUT (WATT)
Heat pump
Cooling
75
80
105
107
131
178
231
Cooling
75
80
105
107
131
178
231
Cooling only
12
18
24
28
1.5
1.5
1.5
2 x 1.0 2 x 1.0 2 x 1.0 2 x 1.0
+
+
+
1.0
1.0
2 x 0.5 2 x 0.5 2 x 0.5 2 x 0.5
230
230
230
400
(*)
(*)
3N
6,5
10.8
10.8
7.5
8
12
12
10
Quantity
Use
1
Indoor unit installation
1
Correct use
1
Air renewal
230V-240V ~ 60Hz
E N G L I S H
Heating
75
80
105
107
131
178
231
Heating
1575
1580
1605
2107
2131
2178
2231
36
48
60
+
+
+
400
400
400
3N
3N
3N
7.5
7.5
7.5
10
10
10
GB - 3