Shipping Handles; Venting - Napoleon LHD62N Installation And Operating Instructions Manual

Natural gas propane
Table of Contents

Advertisement

2.5

SHIPPING HANDLES

IMPORTANT
This appliance fully dressed weighs 575lbs (261kg).
Shipping brackets were shipped secured to the appliance. The unit can be lifted by inserting the shipping
handle through a set of holes. Shipping brackets must eventually be removed if framing to minimum enclosure
dimensions.
When preparing to lift the appliance follow the directions and illustrations provided.
1.
Locate the shipping handles provided with the bolts and wing nuts already attached.
2.
Remove the bolt and wing nut from one end of the shipping handle and insert it into the appropriate set
of holes on the shipping bracket, most comfortable for lifting the appliance, as shown below.
3.
Once the shipping handle is through the holes, reattach the bolt and wing nut to the handle, ensuring
they are secured on the outer sides of the shipping brackets, as shown below.
4.
Repeat these steps to secure the second shipping handle on the opposite side of the appliance.
5.
In all applications, the shipping handles must be removed once the appliance is located in it's
fi nal position.
SHIPPING
HANDLE

3.0 VENTING

RISK OF FIRE, MAINTAIN SPECIFIED AIR SPACE CLEARANCES TO VENT PIPE AND APPLIANCE.
IF VENTING IS INCLUDED WITH SPACERS THE VENT SYSTEM MUST BE SUPPORTED EVERY 3FT
(0.9m) FOR BOTH VERTICAL AND HORIZONTAL RUNS. USE SUPPORTS OR EQUIVALENT
NON-COMBUSTIBLE STRAPPING TO MAINTAIN THE REQUIRED CLEARANCE FROM
COMBUSTIBLES. USE WOLF STEEL LTD. SUPPORT RING ASSEMBLY W010-0370 OR EQUIVALENT
NON-COMBUSTIBLE STRAPPING TO MAINTAIN THE MINIMUM CLEARANCE TO COMBUSTIBLES
FOR BOTH VERTICAL AND HORIZONTAL RUNS. SPACERS ARE ATTACHED TO THE INNER PIPE AT
PREDETERMINED INTERVALS TO MAINTAIN AN EVEN AIR GAP TO THE OUTER PIPE. THIS GAP IS
REQUIRED FOR SAFE OPERATION. A SPACER IS REQUIRED AT THE START, MIDDLE AND END OF
EACH ELBOW TO ENSURE THIS GAP IS MAINTAINED. THESE SPACERS MUST NOT BE REMOVED.
This fi replaces uses 8" (203.2mm) exhaust / 10" (254mm) air intake vent pipe system.
For safe and proper operation of the fi replace follow the venting instruction exactly. Deviation from the minimum
vertical vent length can create diffi culty in burner start-up and/or carboning. Under extreme vent confi gurations,
allow several minutes (5-15) for the fl ame to stabilize after ignition. Provide a means for visually checking the vent
connection to the fi replace after the fi replace is installed. Use a fi restop, vent pipe shield or attic insulation shield
when penetrating interior walls, fl oor or ceiling.
NOTE: If for any reason the vent air intake system is disassembled; reinstall per the instructions provided
for the initial installation.
SHIPPING
BRACKETS
WARNING
!
Refer to the section applicable to your installation.
9
7.3B
W415-1068 / B / 01.02.14
EN

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lhd62p

Table of Contents