Figure H18: Dockside Inlet Location
Figure H19: Cablemaster Switch Location
The V458 models have main circuit breakers on the
240V AC panel labeled SHORE and GENERATOR.
See Figures H4 & H20.
Figure H20: 240V AC Cabin Panel - Main Breakers
Electrical Systems - Section H
The respective main breakers must be turned ON
and the boat must either be connected to shore power
or the generator must be running for AC system
operation. Note: An AC slide lockout is installed on
the MAIN breaker switches to prevent energizing
both the SHORE and GENERATOR systems simulta-
neously thus preventing possible damage to the
electrical system.
Never override the AC slide lockout mechan-
ism. Damage to the electrical system and
possible fire and/or death could result.
These main circuit breakers protect both the hot and
neutral input leads. These breakers are sensitive. The
resulting power surge which occurs when connect ing
the shore power cable may cause the MAIN breakers
to trip. To avoid this power spike, turn OFF the
SHORE break ers before connecting to the shore
station power. Securely connect the boats shore
power cable to the shore power station's receptacle.
Once the shore power is securely connected, turn
the MAIN breakers back on. If the connection is
broken and later re-secured, the circuit breaker may
trip. Connections must be secure for unin terrupt ed
dockside service.
The AC voltage for the shore power AC or generator
systems may be monitored with the voltmeter in the
AC panel. The SHORE or GENERATOR voltage is
automatically monitored when that particular system
is activated/energized. See Figure H20.
Also on the AC main distribution panel is an ammeter
and on certain models an ammeter selector switch.
See Figure H21.
Figure H21: Ammeter & Selector Switch