C. Dockside Waste Pump Out
On most V Series models waste pump out capability
is available. Waste can be removed from the holding
tank by taking the boat to a dockside waste pumping
station. Most marina fueling facilities provide such
services.
The waste holding tank should be emptied when
the waste level indicator reads full. The waste level
indicator is located on the 12VDC cabin panel.
See Figure J16. DO NOT ALLOW THE WASTE
TANK TO BECOME OVERFILLED.
To pump out the holding tank:
1. Be sure the head has some water in the bowl.
2. Connect the dockside pump out connection to the
WASTE plate located on the deck. See Figure
J17.
Figure J17: Waste Pumpout Fitting Location
NOTICE
Usual ly the dockside pump out connection will
screw into the waste deck plate or has a
rubber sleeve that inserts into the plate and
must be held in position during the pump out
operation. If the hose is not air tight or connect-
ed prop erly, waste could spurt out or leak
around the deck fitting and into the boat.
3. Have the pumping station operator activate the
pumping equipment. The waste will be drawn from
the holding tank and into the pumping station's
disposal tank.
Water and Waste Systems - Section J
4. Remove the pump out con nection from the deck
5. Repeat steps 2 & 3 above to pump out the water
6. Add waste holding tank treatment chemical to the
J - 8
Bow
Information supplied with water and waste system
compo nents by the equipment manufacturers is
included with this manual. Refer to this literature for
addi tional operation and service information.
Be sure the batteries in the boat are properly charged.
Operating the pressure pump from a battery with a
low charge will result in pump cycling. This could lead
WASTE Plate
to prema ture pump failure.
A. Clean Vents and Screens
Periodically, inspect the water tank vents and thru-hull
vent fittings for any dirt, wax, etc. Carefully remove
any obstruction with a pipe cleaner or similar device.
Be sure not to puncture the screen. The stainless
steel vent cap is not removable.
plate. Add at least 5 gallons of clean water to the
hold ing tank on most models through the waste
deck fitting using a dockside water hose.
used in step 4 to flush the holding tank.
head bowl. It is available from the dockside
pumping station or can be obtained from your
dealer. Flush at least twice.
Be careful when handling and storing
treatment chem i cals. Not only are they toxic,
but they will also stain and damage
surrounding sur face.
SYSTEM MAINTE NANCE
The decomposition of waste produces a
colorless, odorless gas, methane, that is lighter
than air, combusti ble, and ex treme ly le thal.
Always provide sufficient ventila tion when
effecting repairs to the waste sys tem and allow
no odor from the waste system to go
unresolved.
Owner's Manual Page 102