2.14 Installer Mode; 2.15 Installer Menu - Bosch DS7200V2-EXP Installation Manual

Table of Contents

Advertisement

DS7200V2-EXP | Installation Guide | 2. System Installation
and Setup

2.14 Installer Mode

Use of the Installer PIN might be
restricted. See Keypad Response
Options on page 75 for information on
enabling/restricting the Installer PIN.
When all areas configured in the control panel are
disarmed, the Installer Menu can be accessed
from any LCD keypad by entering [Installer
PIN][#][4][1] or [#][4][1][Installer PIN].
The default Installer PIN is 9876.
Close the Installer Switch when using an Installer
Keypad.
If any area configured in the control panel is
armed, only the Installer Keypad can access the
Installer Menu. After 20 min. of inactivity, the
Installer Menu is automatically exited. The control
panel resets if it was in programming mode.
If the Installer Switch is closed when the control
panel powers up, the control panel completes its
power up. It then checks if there is an Installer
Keypad. If not, it finds the text keypad with the
lowest address. The first keypad found is placed
in the Installer Menu with installer rights, and the
20-minute timer is started.
If [8] is pressed to enter keypad programming,
the control panel enters keypad programming
even if keypad programming is disabled. When
the Installer Menu is exited, the control panel
reverts to normal operation.

2.15 Installer Menu

The Installer Menu consists of the following
choices (the numbers preceding the descriptions
represent the keypad number key to press):
1: Bell Test
2: Strobe Test
3: Battery Test
4: Test Report
5: Zone Status
6: Output Test
7: RF Menu
8: Keypad Program
9: Program Key (PK32)
0: Call for Service
The following sections explain each menu choice.
Bosch Security Systems, Inc. | 04/12 | F01U253045-02
2.15.1 Bell Test
Press [1] to initiate a Bell Test.
The control panel activates the Bell Time (Output
Function Type 1|5) and Alarm Output (Output
Function Types 1|8 to 1|12, and 8|8) functions for
3 sec.
For a complete description of output functions,
see Output Parameters on page 86.
2.15.2 Strobe Test
Press [2] to initiate a strobe test.
The control panel activates the Strobe Output
functions and waits for the installer to press [#]
to end the test. If the installer fails to press [#]
within 20 min, the control panel automatically
terminates the strobe test.
2.15.3 Battery Test
Press [3] to initiate a battery test.
The battery test causes the system to run on
battery for 4 min.. If the battery voltage falls
below 12.1 V during the 4-minute test, or if the
battery is missing, the system restores AC power
and displays a system trouble at all keypads.
2.15.4 Test Report
Press [4] to send a test report.
The control panel attempts to send a test report.
If there is a system trouble at the time of the test,
the control panel sends a "Test, Off Normal"
report.
If the test communication is unsuccessful, the
control panel creates a system trouble and a
communication failure.
2.15.5 Zone Status
Press [5] to display zone/sensor loop status for
the first location in the system.
The location, zone number and electrical status
(Open, Short, Normal, or Fault) are shown. See
Zone Parameters on page 80 for a complete
description of the relationship between locations,
areas and zones.
Press [*] to advance to the status for the next
zone. Press [#] to exit the Zone Status mode.
A closed DACM door contact displays
as "Normal." If "Use Tamper-Wired
Processing" is enabled in DACM
Global Options (page 107), an open
door contact displays as "Fault." If
this option is disabled, an open door
contact displays as "Short."