System Installation And Setup; Control Panel Installation; Figure 1: Enclosure Installation - Bosch DS7200V2-EXP Installation Manual

Table of Contents

Advertisement

DS7200V2-EXP | Installation Guide | 2. System Installation
and Setup
2.
System Installation and
Setup
2.1

Control Panel Installation

The control panel and enclosure are shipped
together. Hardware to attach the enclosure to the
wall is not supplied.
Only qualified, authorized service
personnel should install and maintain
this system. Test the entire system at
least once a week, and have a
qualified technician check the system
at a minimum of once every three
years.
As this is permanently connected
equipment, a readily accessible
disconnect device shall be
incorporated into the building
installation wiring.
The control panel contains static-
sensitive components and must be
handled with care. Follow anti-static
procedures when handling it.
Touch the control panel's earth
ground terminal to discharge any
static charge you may be carrying
before working on it.
2.1.1
Electro Magnetic Interference (EMI)
EMI might occur if you install the system or run
system wires near any of the following:
Computer network system
Electrical lines, fluorescent fixtures, or
telephone lines
Amateur radio transmitter site
Heavy machinery and motors
High voltage electrical equipment or
transformers
PBX telephone system
Public service (police, fire, etc.) using radio
communications
Radio station transmitter site or other
broadcast station equipment
Welding shop
Bosch Security Systems, Inc. | 04/12 | F01U253045-02
If you think that EMI could be a problem, use
shielded cable. The drain wire for the shielded
cable must have continuity from the earth ground
terminal on the control panel to the end of the
wire run. If continuity is not maintained, the
shielded cable can aggravate potential noise
problems rather than eliminate them.
Connecting the drain wire to ground at any place
other than the control panel's earth ground
terminal might also create problems. If you cut
the drain wire to install devices, be certain to
splice it together. Carefully solder and tape all
splices.
2.1.2
Enclosure Installation
Knock out the desired wire entrances on the
enclosure.
Use the enclosure as a template and mark the top
mounting holes on the mounting surface.
Pre-start the screws (not supplied) for these
holes.
Place the enclosure onto these screws. See
Figure 1.
Tighten the screws.
Screw in the remaining two screws into the
bottom holes. See Figure 1.
Use proper anchor and screw sets
when installing the enclosure on
non-load-bearing surfaces, such as
dry wall.
Use the screws provided to secure
the enclosure cover (see Figure 1).

Figure 1: Enclosure Installation

2
1
1- Screws for securing the cover
2- Slide enclosure screws into upper portion of
mounting hole
3- Top holes
4- Bottom holes
EN | 11