Theory of Operation Ver. 8.0 Jun. 2008
11.1.3
Cleaning/main erase mechanism
A. Main erase lamp/K control
• IU/K has a main erase lamp/K located on the upstream side of the cleaning blade to
improve cleaning performance.
• Main erase lamp/K radiation onto the surface of the PC drum removes electric charge
remaining on the surface and makes the cleaning operation by the cleaning blade easier.
< IU/K >
PC drum/K
Cleaning blade
Main erase lamp/K (EL/K)
(Main body)
Toner collecting screw
A00JT2C013DA
11. Charge Corona section
Cleaning blade
A00JT2C036AA