10. Slide the expansion-slot clip toward the server until it snaps into place to
11. Connect any internal cables to the adapter. See the instructions that come with
12. If you removed the power-cord module to install the adapter in PCI-X slot 2,
13. If you installed the adapter in PCI-X slot 1, secure the adapter by flexing the
14. Perform any configuration tasks required for the adapter.
15. If you have other options to install, install them now. Otherwise, go to
14
326 Type 8848: Installation Guide
b. Lift and place the power-cord module out of the server as far as the power
supply cable permits.
9. Install the adapter.
Attention:
When you handle static-sensitive devices, take precautions to
avoid damage from static electricity. For information about handling these
devices, see "Handling static-sensitive devices" on page 7.
a. Remove the adapter from the static-protective package and set any
jumpers or switches on the adapter as directed by the adapter
manufacturer. If you are installing a full-length adapter, you might have to
remove a plastic bracket secured to the adapter with two screws before
installing the adapter.
Attention:
When you install an adapter, make sure that the adapter is
correctly seated in the connector before you turn on the server. Improperly
seated adapters might cause damage to the system board, the riser card,
or the adapter.
b. If you are installing an adapter in PCI-X slot 1, attach the PCI riser card to
the adapter. Reinstall the PCI riser card with the adapter already attached
to the PCI riser card.
c. Grasp the adapter by its top edge or upper corners, align it with the
connector, and press it firmly into the connector.
secure the adapter in the adapter slot.
the adapter for details.
Attention:
Make sure that the cables do not block the flow of air from the
fans.
install the module by reversing the procedure in step 8a on page 13. Make
sure that the alignment tab is fully seated in the slot on the side of the server.
adapter-retention bracket toward the front of the server and inserting the front
corners of the adapter into the recesses in the latch.
If you installed a Remote Supervisor Adapter II, see the documentation that
comes with the Remote Supervisor Adapter II for information about installing
the Remote Supervisor Adapter II firmware and configuring the adapter. After
you initially configure the adapter, create a backup copy of the configuration so
that if you need to replace the adapter in the future, you can restore the
configuration and resume normal operation more quickly.
"Completing the installation" on page 24.