DIP switch settings

Applicable models and REU numbers
Rinnai Infinity VT16
Rinnai Infinity VT20
Rinnai Infinity VT24
Rinnai Infinity VT26
Rinnai Infinity EF24
DIP switch 1: Upper SW (8P)
SW No.
Note
1
Fixed temperature
2
(with controllers)
3
4
Temperature settings
5
6
7
Gas pressure
8
Chart A: Temperature settings
DIP. SW.1-SW No. (8P)
3
4
Off
Off
On
Off
Off
On
On
On
Off
Off
On
Off
Off
On
On
On
DIP switch 2: Lower SW (4P)
SW No.
Note
1
Gas type
2,3,4
Model settings
Chart B: Model settings
DIP. SW.2-SW No. (4P)
2
3
Off
Off
Off
On
Off
Off
Off
On
24 | Continuous Flow Water Heater Installation Guide 04-12
External
REU-VR1620WG
External
REU-VR2024WG
External
REU-VR2426WG
External
REU-VR2626WG
External
REU-K2430WG
Off
Off
Fixed temperature
See Chart A
Off
Off
Normal
Off
SW No. 2 = Off
(fixed temperature)
5
No controllers
(fixed temp.)
Off
55
Off
75
Off
65
Off
60
On
50
On
42
On
not to be used
On
not to be used
Off
LPG
See Chart B
Model (REU-number)
4
Off
VT26 (VR2626WG) and EF24 (K2430WG)
Off
VT24 (VR2426WG)
On
VT20 (VR2024WG)
On
VT16 (VR1620WG)
On
Forced min.
Off
SW No. 2 = On
(with controllers)
No controllers (fixed
temp.)
55
55
55
55
50
42
40
55
On
NG
On
On With controllers
On
Forced max.
On
With controllers
(max. set temp.)
55
75
65
60
50
42
40
75
Off