Electrical Specifications; Leveling Information; Installation Tip; 09/2007 - U-Line Echelon 2275DWRR Installation Manual

Refrigerator drawer echelon series
Hide thumbs Also See for Echelon 2275DWRR:
Table of Contents

Advertisement

6 Prepare Power Supply

Electrical Specifications

CAUTION
Electrical installation must observe all state and local
codes. This unit requires connection to a grounded (three-
prong), polarized receptacle that has been placed by a
qualified electrician.
The unit requires a grounded and polarized 115 VAC,
60 Hz, 15A power supply (normal household current).
An individual, properly grounded branch circuit or circuit
breaker is recommended. GFCI (ground fault circuit
interrupter) is usually not required for fixed location
appliances and is not recommended for your unit because
a GFCI could be prone to nuisance tripping. However, be
sure to consult your local codes.
See Figure 23 for recommended receptacle location.
1-1/2"
Figure 23
WARNING
SHOCK HAZARD — Electrical Grounding Required.
• Never remove the round grounding prong from
the plug and never use a two-prong grounding
adapter.
• Never use an extension cord to connect power to
the unit.
Go on to 7 Level the Unit.
www.U-LineService.com

2275DWRR — Drawer Model Refrigerator

23-11/16"
7"
7 Level the Unit

Leveling Information

Note: It is recommended that the unit is level.
1. Use a level to
check the
levelness of the
unit from front to
back and from
side to side. Level
should be placed
along top edge
and side edge as
shown (see
Figure 24).
2. If the unit is not
level, adjust the
feet on the
corners of the unit
as necessary (see
Figure 25).
Figure 25
3. Check the levelness after each adjustment and repeat
the previous steps until the unit is level. Go on to
8 Install the Unit.

Installation Tip

If the room floor is higher than the floor in the cut-out
opening, adjust the rear feet to achieve a total unit rear
height of 1/8" less than the opening's rear height. Shorten
the unit height in the front by adjusting the front feet.
This allows the unit to be gently tipped into the opening.
Readjust the front feet to level the unit after it is correctly
positioned in the opening.
12
Figure 24
ULIN_0045_A
ULIN_0046_A

09/2007

Advertisement

Table of Contents
loading

Table of Contents