Iwatsu ADIX-VS Technical Manual page 26

Digital telecommunications system
Hide thumbs Also See for ADIX-VS:
Table of Contents

Advertisement

ADIX-VS Technical Manual
Do not place the VS-KSU Control Module in the following areas:
Near a sprinkler system, sweating pipes, steam pipes or steam vents.
In an extremely hot or cold area. Do not install the unit in an environment that does not
meet the requirements specified on page 15.
In direct sunlight.
In a passage used for moving equipment.
In areas where airborne contaminants, dust, corrosive fumes, or exhaust from machinery is
present.
In areas where high power radio frequency transmitters, transmission cables, or other
sources of Electromagnetic Interference are installed 10 feet from a large commercial
transformer.
Figure 1 illustrates a typical installation layout for a typical ADIX-VS system.
To Central Office
SLT2
KT6
KT4
KT2
SLT1
KT5
KT3
KT1
FIGURE 1. ADIX-VS INSTALLATION LAYOUT.
Note 1:
When the VS-ICOTB card is installed, an NT1 device is also required. The NT1 device must
be mounted near the VS-KSU. Iwatsu does not supply the NT1 device.
Note 2: It is not necessary to install protective fusing on all analog CO trunk circuits. ADIX-VS
provides UL listed fuse protectors on the analog CO trunk card.
CN6
CN2
s1
DC
1 2 3
4
5
6
7
8
OUTPUT
AC
1
BAT1
BAT2
0
CN1
AC
Outlet
Commercial
Ground
To Extensions
16
Section 1 – Introduction