Iwatsu ADIX-VS Technical Manual page 110

Digital telecommunications system
Hide thumbs Also See for ADIX-VS:
Table of Contents

Advertisement

ADIX-VS Technical Manual
On-Site PC Programmer
An IBM compatible XT/AT personal computer can be used to program or change the ADIX-VS
database. The motherboard (VS-MAIN) card is required for serial communication.
)
Setup and Programming:
1. Plug the serial cable into the connector labeld PC/MODEM on the motherboard(VS-MAIN)
card as illustrated Figure 51.
2. Plug the other side of the cable into a COM1 or COM2 serial port on the PC. Use an
extension cable or DB9 to DB25 conversion connector if neccessary.
3. Program the RS232C port using Class 01.03-Port Definition.
FIGURE 51. ON-SITE PC PROGRAMMING CONNECTION
CN6
CN2
s1
DC
OUTPUT
1 2 3
4
5
6
7
8
AC
1
BAT1
BAT2
0
CN1
SLT2 SLT1 KT6 KT5 KT4 KT3 KT2 KT1
PRNTER
PC/MODEM
MOH
Section 3 – ADIX-VS Installation
Adapter
PC Programmerr
100