B. Vent Components Diagrams (continued)
8-1/8 in.
(206 mm)
15 in.
(381 mm)
COAXIAL to COLINEAR VENTING
LINK-DV30B
Flex Liner Kit
Figure 13.5 DVP vent components
64
Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. G • 9/14
13 in.
Effective Length
(330 mm)
5-3/4 to 8-3/8 in.
146 to 213 mm
WARNING
Fire Risk.
• When using DVP-HRC-SS and DVP-HRC-ZC-
SS termination caps on top vented fi replaces, a
6 inch minimum vertical vent section is required
before installing fi rst elbow.
DVP-HRC-SS
DVP-HRC-ZC-SS
HORIZONTAL TERMINATION CAP
768-380A
Stainless Steel Flex Pipe
DVP-2SL
Adapter
5-1/2 in.
8-3/8 in.
140 mm
213 mm
87°
10-1/2 in.
267 mm
10-7/8 in.
276 mm
DV-46DVA-GCL
Coaxial/Colinear Appliance Connector