Heat & Glo Revo-V12 Installation Manual page 34

Heat & glo direct vent heater installation manual
Hide thumbs Also See for Revo-V12:
Table of Contents

Advertisement

APPLIANCE OUTER WRAP
FIRESTOP INSTALLATION HOLES
Figure 6.10. Install Firestop and Firestop Framing
(A)
MASONRY
SHEET ROCK
ANCHORS
WASHER (2)
Figure 6.11 Masonry Anchors and Sheet Rock Anchors
1 = FIRESTOP FRAMING HOLES SHADED
2 = FIRESTOP HOLES
3 = SHEETROCK ANCHOR HOLES
SEE FIGURE 6.11(B)
4 = VERTICAL STUD ATTACHMENT HOLES
NOTICE: A minimum of two screws must be
attached to the vertical wall studs
5 = OPTIONAL ATTACHMENT HOLES
Figure 6.12 Outer Wrap Mounting Feature Identifi cation
34
Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. G • 9/14
(B)
(C)
ATTACHMENT
SCREWS (12)
ANCHORS
ANCHOR (2)
ASSEMBLED
APPLIANCE OUTER WRAP
WITH FIRESTOP FRAMING
FIRESTOP
CUT OUT
FIRESTOP FRAMING
LOCATED BEHIND
OUTER WRAP AND
SHEET ROCK
8. When attaching to a brick (masonry) wall, use masonry
anchors. See Figure 6.11 (A).
9. A minimum of two screws must be used to attach the
appliance to vertical wall studs. See Figure 6.11 (C).
Use sheet rock anchors if a wall stud is not available
on either or both sides of the appliance outer wrap.
See Figure 6.11 (B).
10. Install the fi rebox onto the outer wrap as directed in
Section 6.D.
11. Replace the glass assembly on the appliance. Latch
the two bottom glass assembly latches and then the
two top glass latches. See Figure 12.1.
12. Attach the appliance vent system. See Section 6.A for
reference to sealing fi restop. An SLP-TRAP2 will be
needed when hanging the appliance on a 2 x 6 wall.
4
2
3
1
4
5
FIRESTOP INSTALLED
FIRESTOP
INSTALLED
1
2
3
5
4
1
4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Revo-s21Revo-h31

Table of Contents