Heat & Glo Revo-V12 Installation Manual page 54

Heat & glo direct vent heater installation manual
Hide thumbs Also See for Revo-V12:
Table of Contents

Advertisement

4. Insulate wall per local code requirements. Use Ther-
max where an R19 insulation value is required.
See Figure 11.3 (C) and Figure 11.6.
5. Install In-Wall Tub as shown in Figure 11.3 (D). The
tub should set on the framing. Verify hood clips are in
the correct orientation. See Figure 11.5. Ensure tub is
level. Use eight screws (supplied with In-Wall Kit) to
attach the tub to the framing.
CAUTION! In-Wall Tub and Appliance Outer Wrap
MUST be installed level for proper burner operation.
6. Install the required non-combustible board (supplied)
as shown in Figure 11.3 (E) using six screws.
WARNING! Risk of Fire! DO NOT apply combustible
materials beyond the minimum clearances. Comply with
all minimum clearances to combustibles as specifi ed in
this instruction. Overlapping materials could ignite and
will interfere with doors.
7. Cut through insulation and wall as shown in Figure
11.3(E). Allow space for clearance for the fi restop
framing disussed in step 11.
8. Remove the glass assembly from the fi rebox by re-
leasing the two top glass latches and then the two
bottom glass latches. See Figure 12.1.
9. Remove fi rebox from outer wrap. See Figure 6.8.
10. Install the outer wrap as shown in Figure 3 (F & G)
using the four supplied bolts in the threaded holes.
Additional screws may be installed to ensure the tub
CAP EXTENSION
CAULK
PERIMETER
(EDGE)
CAULK
PERIMETER
CAP EXTENSION INSTALLED
Figure 11.4 Cap Extension Installation
54
Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. G • 9/14
SLP-TRAP1 CAP
and the outer wrap are secured fl at to one another.
11. Frame around the edges of the fi restop cut out to en-
sure insulation does not come into contact with the
vent pipe. See Figure 6.10 and 6.12.
12. Install fi restop using the four supplied screws. See
Figure 6.10 and 6.11. See Section 6.A for reference
to sealing fi restop.
13. Install fi nishing strips if applicable. See Figure 11.5.
14. Reattach fi rebox to outer wrap. Use Figure 6.8 and
6.13 for reference.
15. Replace the glass assembly on the appliance. Latch
the two bottom glass assembly latches and then the
two top glass latches. See Figure 12.1.
16. Attach the appliance vent system. See Section 6.A
for reference to sealing fi restop.
NOTICE! Install a cap extension if gap exists between
the wall and the back of the termination cap. See Figure
11.4. An SLP-TRAP1 will generally be used with In-Wall
installations.
17. Install vent and trap cap extension if a gap exists be-
tween the exterior wall and the cap. To prevent drafts,
the cap extension should be sealed with caulk that
has a minimum of 300ºF continuous exposure rating
to seal gaps of the extension. See Figure 11.4.
NO
EXTENSION
GAP
CAP
EXTENSION
INSTALLED
TO ELIMINATE
GAP
2 X 6 WALL

Advertisement