Clearances; Mantel Requirements - Lopi Radiant Plus GSB2 Owner's Manual

Large insert
Hide thumbs Also See for Radiant Plus GSB2:
Table of Contents

Advertisement

Installation (for qualified installers only)

Clearances

Due to the high temperature of the heater, it should be located out of traffic and away from furniture
and draperies.
k Sidewall to Insert
l Side Facing (non-combustible)
m Top Facing*(non-combustible)
n Mantel** (combustible or non-combustible)
x Hearth Extension
*
The non-combustible top facing must extend 38" (966mm) above the base of the insert or to the
bottom of the mantel (whichever is less).
** The combustible area above the non-combustible facing must not protrude more than 3/4"
(20mm) from the facing. If it does, it is considered a mantel and must meet the mantel
requirements listed in this manual..

Mantel Requirements

The maximum mantel depth is 12" (305mm).
© Travis Industries
Minimum Clearances
5" (127mm)
5" (127mm)
38" (966mm)
36-1/2" (928mm)
0" (0mm)
4/23/2021 - 1449
11
Radiant Large GSB2