4.0 CHimNEy iNSTALLATiON

Never install a single wall slip section or smoke pipe in a chase structure. The higher temperature of this
single wall pipe may radiate sufficient heat to combustible chase materials to cause a fire.
To avoid danger of fire, all instructions must be strictly followed, including the provision of air space
clearance between chimney system and enclosure. To protect against the effects of corrosion on those
parts exposed to the weather, we recommend that the chase top be painted with a rust-resistant paint.
Maintain a minimum 2" air clearance to all parts of the chimney system at all times. Failure to maintain this
Detailed instructions for installation of the chase top, storm collar and termination cap are packaged with
Firestop spacers must be used whenever the chimney penetrates a ceiling/floor area.
To avoid danger of fire, all instructions must be strictly followed, including the provision of air space
clearance between chimney system and chase. To protect against the effects of corrosion on those parts
exposed to the weather, we recommend that the chase top be painted with a rust-resistant paint.
TP - 7" CHIMNEY
W415-0711 / 10.03.08
2" air clearance will cause a structure fire.
these parts.
FIGURE 4.0a