4038-001
Dead machine
FRU
Line voltage
LVPS/HVPS to system
board cable
LVPS/HVPS
2-32
Service Manual
Action
Check the AC line voltage to make
sure it is correct.
Ensure the cable connecting the
LVPS/HVPS to the system board is
properly seated.
Check the following voltages on CN2
of the LVPS/HVPS:
• pin 3, +5 V dc
• pin 4, +5 V dc
• pin 5, Ground
• pin 6, Ground
• pin 7, +12 V dc
• pin 8,9,10,11, Ground
• pin 12, +24 V dc
If any of the voltage measurements
are not correct, replace the LVPS/
HVPS.