17. The display reads:
Recipe Timing
Use the PROGRAM ARROW KEYS (4) to select ei-
ther Yes or No. Press the PROGRAM KEY (3).
18. The display reads
Global Timing
Definition: There are 3 options for timing
mode when shelf cooking: Straight, Flex and
Sensitivity. Straight has no time adjustment.
Flex adjusts the cook time to compensate for
any difference between the setpoint and actual
temperature. Sensitivity enables a product key
to have a flex adjustment for each of the five
shelves. Sensitivity values are set in the man-
ager level programming.
Use the PROGRAM ARROW KEYS (4) to select the
timing mode. Press the PROGRAM KEY (3).
Programming the PRodUct naMe
NOTE: Use these instructions to modify an existing
name, to add a product name or to delete a
name already in the library.
NOTE: Names may be up to 16 characters long and can
contain letters and numbers.
1. After entering the manager level programming (see
page 36) the display reads:
System
Prod Name Lib
With ProdName Lib highlighted, press the PRO-
GRAM KEY (3) to select. The display reads:
Product Name Lib
YES
YES
2. Use the up and down PROGRAM ARROW KEYS (4)
to scroll through the existing product names. Or press
the PRODUCT KEY (14) that corresponds with the
first letter of the name you are looking for. Then use
the PROGRAM ARROW KEYS (4) to scroll to the de-
sired name.
3. Press the SCAN KEY (9) to edit the name.
4. Use the PRODUCT KEYS (14) to edit the product
name. Press the right arrow key to advance to the
next character.
To clear the product name, press the TEMP/TOG-
GLE/CLEAR KEY (11).
NOTE: Use product key 1 for spaces, periods, quo-
tation marks and underlines.
5. Once the product name has been entered, press the
PROGRAM KEY (3). The display reads:
Use the PROGRAM ARROW KEYS (4) to select ei-
ther ADD, MODIFY or CANCEL. Select ADD to cre-
ate a new product name. Select MODIFY to change
an existing product name. Select CANCEL to exit the
edit mode without saving your changes.
NOTE: To delete an exsisting product name, find
the name in the product library. Press
the TEMP/TOGGLE/CLEAR KEY (11) to
clear the entire product name. Then select
MODIFY to overwrite the name with a clear
screen.
6. Press the PROGRAM KEY (3) to exit the product
name library.