Milli-Volt Control Lighting Instructions - Vermont Castings DFS3224A Installation And Operating Instructions Manual

Vent-free fireplace systems
Table of Contents

Advertisement

OPERATING INSTRUCTIONS
1. STOP! Read the safety information label.
2. Make sure the manual shutoff valve is fully open.
3. This gas log set is equipped with an ignition device (piezo) which automatically lights the pilot. If piezo
ignitor does not light the pilot, refer to instructions for "Match Lighting Instructions", page 29.
4. Turn gas control knob clockwise
and turn ON/OFF switch to OFF position.
5. Wait (5) minutes to clear out any gas. Then smell for gas, including near the fl oor. If you smell gas, STOP!
Follow "What to Do if You Smell Gas", page 25. If you don't smell gas, go to next step.
6. From OFF position, turn the gas control knob counterclockwise
in control knob for 5 seconds. NOTE: If you are running the heater for the fi rst time, it
will be necessary to press in the control knob for 30 seconds to allow air to bleed
out of the gas piping.
7. With the control knob pushed in, push in and release the piezo ignitor button to light the pilot.
8. Continue pushing the control knob in for a further 10 seconds to prevent the fl ame detector from shutting
off the gas while the probe is warming up. Release the control knob.
9. Turn gas control knob counterclockwise
10. After the pilot has been lit for one minute, the burners can be turned on. Turn the ON/OFF switch to
ON position or adjust thermostat to desired setting.
11. If the gas logs will not operate, follow the instructions "To Turn Off Gas To Heater" below and call
your service technician or gas supplier.
Figure 35 - Pilot
1. Turn control knob clockwise
1. Turn control knob clockwise
2. If applicable: Turn ON/OFF switch to OFF position and/or set thermostat (if present) to lowest setting.
2. If applicable: Turn ON/OFF switch to OFF position and/or set thermostat (if present) to lowest setting.
3. If applicable: Turn off all electric power to the heater.
3. If applicable: Turn off all electric power to the heater.
28
MILLI-VOLT/THERMOSTAT CONTROL
LIGHTING INSTRUCTIONS
Hi/Lo Control
Hi/Lo Control
TO TURN OFF GAS TO HEATER
to the OFF position, set the thermostat to the lowest setting
to the ON position.
Ignitor Pilot Control
Figure 36 - Control Cover Plate for Milli-Volt
to OFF position to completely shut off the heater.
to IGN position. Push
On/Off Switch
Piezo
26D3310