Download Print this page
Goodman GMEC80 Series Manual

Goodman GMEC80 Series Manual

Two-stage, multi-speed ecm gas furnace 80% afue
Hide thumbs Also See for GMEC80 Series:

Advertisement

Heating Input: 40,000-120,000 BTU/h
Standard Features
• Two-stage gas valve provides quiet,
economical heating
• Efficient and quiet multi-speed ECM circulator motor
• SureStart® Silicon Nitride igniter
designed for long igniter life
• Self-diagnostic control board
• Low constant fan speed circulates air
throughout the home
• Quiet, two-speed induced draft blower
• California Low NOx emissions-compliant
models available
• Can no longer be installed in California's
South Coast Air Quality Management District
(SCAQMD) on or after October 1, 2019.
• AHRI Certified; ETL Listed
SS-GMEC80/GCEC80
Downloaded from
ManualsNet.com
search engine
GMEC80 / GCEC80
Two-Stage, Multi-Speed ECM
Cabinet Features
• Fully insulated, heavy-gauge steel cabinet
with durable baked-enamel finish
• Multi-position installation:
GMEC80: upflow, horizontal left or right
GCEC80: downflow, horizontal left or right
• Removable bottom for side- or
bottom-return applications
• Convenient left or right connection
for gas/electric service
• Cabinet air leakage ≤ 2%
• Coil and furnace fit flush
for most installations
* Complete warranty details available from your local dealer or at www.goodmanmfg.com. To receive
the Lifetime Heat Exchanger Limited Warranty (good for as long as you own your home), 10-Year
Unit Replacement Limited Warranty and 10-Year Parts Limited Warranty, online registration must be
completed within 60 days of installation. Online registration is not required in California or Québec.
www.goodmanmfg.com
Gas Furnace
80% AFUE
Contents
Nomenclature ........................................ 2
Product Specifications ........................... 3
Dimensions ............................................ 5
Accessories ............................................ 6
Airflow Data ........................................... 7
Wiring Diagram ................................... 24
12/21
Supersedes 2/21

Advertisement

loading

Summary of Contents for Goodman GMEC80 Series

  • Page 1: Table Of Contents

    GMEC80 / GCEC80 Two-Stage, Multi-Speed ECM Heating Input: 40,000–120,000 BTU/h Gas Furnace 80% AFUE Contents Nomenclature ........2 Product Specifications ......3 Dimensions ..........5 Accessories ..........6 Airflow Data ........... 7 Wiring Diagram ........24 Standard Features Cabinet Features •...
  • Page 2: Nomenclature

    Nomenclature 7,8,9 13,14 Brand Engineering G - Goodman® Brand Major /Minor Revisions * Not used for inventory control. Configuration M - Upflow/Horizontal N - Natural Gas C - Downflow/Horizontal X - Low NOx Motor Cabinet Width V - Variable Speed ECM / ComfortBridge™...
  • Page 3: Product Specifications

    Specifications GMEC80 GMEC80 GMEC80 GMEC80 GMEC80 GMEC80 GMEC80 GMEC80 GMEC80 GMEC80 GMEC80 0403A* 0603A* 0603B* 0803B* 0804B* 0804C* 0805C* 0805D* 1004C* 1005C* 1205D* Heating Capacity High Fire Input (BTU/h)¹ 40,000 60,000 60,000 80,000 80,000 80,000 80,000 80,000 100,000 100,000 120,000 High Fire Output (BTU/h)¹...
  • Page 4 Specifications GCEC80 GCEC80 GCEC80 GCEC80 GCEC80 GCEC80 0403A* 0603A* 0603B* 0804B* 0805C* 1005C* Heating Capacity High Fire Input (BTU/h)¹ 40,000 60,000 60,000 80,000 80,000 100,000 High Fire Output (BTU/h)¹ Natural Gas 32,000 48,000 48,000 64,000 64,000 80,000 LP Gas 32,000 48,000 48,000 64,000...
  • Page 5: Dimensions

    GMEC80 Dimensions Alternate Gas Inlet Alt. Flue Outlet — Horizontal Left 1¾” 1 ⁄ ” 19½” ➤ 33⅜” Alt. Gas Inlet 27⅞” 20” 23 ⁄ ” Alt. High Voltage High-Voltage Inlet 15” 13¼” Low-Voltage Inlet Alt. Low Voltage 23” ➤ 28”...
  • Page 6: Accessories

    GCEC80 Dimensions ” ⅝” High-Voltage Electrical Low-Voltage Electrical ⅜” Gas Inlet ⅜” ⅜” Minimum Clearances to Combustible Materials Dimensions Model Vent ² Sides Rear Front ¹ GCEC800403A* 14" 12½” GCEC800603A* 14" 12½” GCEC800603B* 17½” 16" Approved for line contact in the horizontal position. ¹...
  • Page 7: Airflow Data

    GCEC800403A* Airflow Data PCBBF139 *CEC800403A* - COOLING STATIC DIP SWITCHES S1-1, S1-2, S1-3 T STAT CALL OFF OFF OFF* 1348 1294 1261 1250 1229 1233 1205 1182 ON OFF OFF ON ON OFF 1348 1294 1261 1250 1229 1233 1205 1182 OFF ON OFF OFF OFF ON...
  • Page 8 GCEC800603A* Airflow Data (cont.) PCBBF139 *CEC800603A*- COOLING STATIC DIP SWITCHES S1-1, S1-2, S1-3 T STAT CALL 1160 1102 1055 1017 OFF OFF OFF* 1411 1356 1313 1272 1235 1198 1162 1127 ON OFF OFF 1160 1102 1055 1017 ON ON OFF 1411 1356 1313...
  • Page 9 GCEC800603B* Airflow Data (cont.) PCBBF139 *CEC800603B* - COOLING STATIC DIP SWITCHES S1-1, S1-2, S1-3 T STAT CALL 1223 1144 1081 OFF OFF OFF* 1395 1332 1272 1207 1136 1074 1007 1032 ON OFF OFF 1223 1144 1081 1032 ON ON OFF 1395 1332 1272...
  • Page 10 GCEC800804B* Airflow Data (cont.) PCBBF139 *CEC800804B* - COOLING STATIC DIP SWITCHES S1-1, S1-2, S1-3 T STAT CALL 1596 1553 1512 1491 1450 1411 1388 1347 OFF OFF OFF* 1757 1713 1691 1664 1625 1588 1552 1522 ON OFF OFF 1596 1553 1512 1491...
  • Page 11 *CEC800805C* Airflow Data (cont.) PCBBF139 *CEC800805C* - COOLING STATIC DIP SWITCHES S1-1, S1-2, S1-3 T STAT CALL 1782 1744 1715 1700 1660 1619 1579 1510 OFF OFF OFF* 2145 2089 2058 2036 2020 2000 1971 1935 1171 ON OFF OFF 1782 1744 1715...
  • Page 12 **EC801005C* Airflow Data (cont.) PCBBF139 **EC801005C* - COOLING STATIC DIP SWITCHES S1-1, S1-2, S1-3 T STAT CALL 1820 1769 1726 1685 1642 1603 1557 1521 OFF OFF OFF* 2235 2185 2139 2108 2076 2032 2000 1964 ON OFF OFF 1820 1769 1726 1685...
  • Page 13 GMEC800403A* Airflow Data (cont.) PCBBF139 *MEC800403A* - COOLING STATIC DIP SWITCHES S1-1, S1-2, S1-3 T STAT CALL 1138 1093 1057 1016 OFF OFF OFF* 1367 1321 1286 1255 1223 1190 1160 1133 ON OFF OFF 1138 1093 1057 1016 ON ON OFF 1367 1321 1286...
  • Page 14 GMEC800603A* Airflow Data (cont.) PCBBF139 *MEC800603A* - COOLING STATIC DIP SWITCHES S1-1, S1-2, S1-3 T STAT CALL 1151 1091 1050 1007 OFF OFF OFF* 1389 1341 1295 1258 1221 1176 1140 1105 ON OFF OFF 1151 1091 1050 1007 ON ON OFF 1389 1341 1295...
  • Page 15 GMEC800603B* Airflow Data (cont.) PCBBF139 *MEC800603B* - COOLING STATIC DIP SWITCHES S1-1, S1-2, S1-3 T STAT CALL 1330 1280 1229 1187 1146 1103 1061 1018 OFF OFF OFF* 1465 1416 1382 1340 1299 1278 1257 1219 ON OFF OFF 1330 1280 1229 1187...
  • Page 16 GMEC800803B* Airflow Data (cont.) PCBBF139 *MEC800803B* - COOLING STATIC DIP SWITCHES S1-1, S1-2, S1-3 T STAT CALL 1160 1107 1060 1011 OFF OFF OFF* 1231 1185 1136 1093 1049 1004 ON OFF OFF 1160 1107 1060 1011 ON ON OFF 1231 1185 1136...
  • Page 17 GMEC800804B* Airflow Data (cont.) PCBBF139 *MEC800804B* - COOLING STATIC DIP SWITCHES S1-1, S1-2, S1-3 T STAT CALL 1574 1521 1481 1439 1398 1374 1335 1295 OFF OFF OFF* 1782 1726 1684 1645 1610 1574 1542 1506 ON OFF OFF 1574 1521 1481 1439...
  • Page 18 GMEC800804C* Airflow Data (cont.) PCBBF139 *MEC800804C* - COOLING STATIC DIP SWITCHES S1-1, S1-2, S1-3 T STAT CALL 1466 1399 1347 1290 1230 1170 1112 1054 OFF OFF OFF* 1904 1832 1777 1727 1678 1630 1579 1523 ON OFF OFF 1466 1399 1347 1290...
  • Page 19 GMEC800805D* Airflow Data (cont.) PCBBF139 *MEC800805D* - COOLING STATIC DIP SWITCHES S1-1, S1-2, S1-3 T STAT CALL 1698 1621 1553 1497 1437 1393 1328 1270 OFF OFF OFF* 2266 2202 2143 2090 2040 1995 1945 1896 1088 ON OFF OFF 1698 1621 1553...
  • Page 20 GMEC800805C* Airflow Data (cont.) PCBBF139 *MEC800805C* - COOLING STATIC DIP SWITCHES S1-1, S1-2, S1-3 T STAT CALL 1583 1536 1515 1478 1434 1383 1317 1265 OFF OFF OFF* 2145 2089 2058 2036 2020 2000 1971 1935 1171 ON OFF OFF 1583 1536 1515...
  • Page 21 GMEC801004C* Airflow Data (cont.) PCBBF139 *MEC801004C* - COOLING STATIC DIP SWITCHES S1-1, S1-2, S1-3 T STAT CALL 1265 1204 1146 1091 1034 OFF OFF OFF* 1598 1547 1509 1464 1417 1387 1340 1295 ON OFF OFF 1265 1204 1146 1091 1034 ON ON OFF 1598...
  • Page 22 GMEC801205D* Airflow Data (cont.) PCBBF139 *MEC801205D* - COOLING STATIC DIP SWITCHES S1-1, S1-2, S1-3 T STAT CALL 1627 1566 1520 1470 1420 1398 1391 1343 OFF OFF OFF* 2226 2165 2126 2083 2048 2011 1983 1945 ON OFF OFF 1627 1566 1520 1470...
  • Page 23 Temperature Rise Range Chart SS-GMEC80/GCEC80 www.goodmanmfg.com Downloaded from ManualsNet.com search engine...
  • Page 24: Wiring Diagram

    HI VOLTAGE FIELD Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. © 2021 • Goodman Manufacturing Company, L.P. • Houston, Texas • Printed in the USA. www.goodmanmfg.com...

This manual is also suitable for:

Gcec80 series