Mobile Home Installation; Pipe Shield Installation - Regency Alterra CS2400 Owners & Installation Manual

Freestanding
Hide thumbs Also See for Alterra CS2400:
Table of Contents

Advertisement

Once you have properly marked the position of your unit and the fl oor protec-
tion as outlined in the Residential Installation items #1 through #8, a supply of
fresh air has to be supplied to your unit. Cut a minimum 4 inch diameter hole
through your outside wall. Use 4" duct pipe with a mesh grill to pipe fresh air
into the back shield area. Place your unit in position and secure it to the fl oor
using two lag bolts 3/8" x 3-1/2" through the two holes inside the pedestal base.
See page 9 for installation instructions.
For Mobile Home units installed in the U.S; the unit must be grounded using
a #8 ground wire with approved termination and star washer.
It is important to maintain the structural integrity of the Mobile Home
fl oor, walls and roof when installing your unit.
Minimum height requirements
must be met. Safe removal of
the chimney system must be
adhered to when transporting
the mobile home.
WARNING: Operate only with door fully
closed - open feed door to feed fi re only.
Source of fresh air into the room or space heater shall be provided
when required.
1) Bend the tabs on the rear heat shield outwards 90 degrees.
2) Secure the tabs on the top of the rear heat shield with ¼" hex screws,
supplied.
.
Regency CS2400 Freestanding Wood Stove

MOBILE HOME INSTALLATION

CAUTION:
WARNING:
WARNING:

PIPE SHIELD INSTALLATION

(For use with both "C" Vent (Single Wall) and residential - Close clearance).
Secured to fl oor with 2 lag bolts.
Left and right tabs - bent at 90°
Installed Pipe Shield
INSTALLATION
4" outside air kit
13