Mobile Home Installation; Pipe Shield Installation - Regency CS2400 Owners & Installation Manual

Hide thumbs Also See for CS2400:
Table of Contents

Advertisement

Once you have properly marked the position of your unit and the floor protec-
tion as outlined in the Residential Installation items #1 through #8, a supply of
fresh air has to be supplied to your unit. Cut a minimum 4 inch diameter hole
through your outside wall. Use 4" duct pipe with a mesh grill to pipe fresh air
into the back shield area. Place your unit in position and secure it to the floor
using two lag bolts 3/8" x 3-1/2" through the two holes inside the pedestal base.
See page 9 for installation instructions.
For Mobile Home units installed in the U.S; the unit must be grounded using
a #8 ground wire with approved termination and star washer.
It is important to maintain the structural integrity of the Mobile Home
floor, walls and roof when installing your unit.
Minimum height requirements
must be met. Safe removal of
the chimney system must be
adhered to when transporting
the mobile home.
WARNING: Operate only with door fully
closed - open feed door to feed fire only.
Source of fresh air into the room or space heater shall be provided
1) Bend the tabs on the rear heat shield outwards 90 degrees.
2) Secure the tabs on the top of the rear heat shield with ¼" hex screws,
supplied.
.

MOBILE HOME INSTALLATION

CAUTION:
WARNING:
WARNING:
when required.

PIPE SHIELD INSTALLATION

(For use with both "C" Vent (Single Wall) and residential - Close clearance).
Secured to floor with 2 lag bolts.
Left and right tabs - bent at 90°
Installed Pipe Shield
Regency CS2400 Freestanding Wood Stove
installation
4" outside air kit
|
13
|
13