2.6 Disassembly of LCD UNIT
(1) Remove one screw (e × 1), disconnect the CN4001, disengage the dowel and claws A and B, and slightly set the LCD
UNIT away from the main unit.
(2) Disconnect the CN502 and then detach the LCD UNIT.
Dowel
CN502
(1) - e
Claw A
CN4001
(2)
(1)
LCD FPC
LCD UNIT
e
Claw B
XA1-7170-307
(1)
3.0mm
CN4001
SILVER
M1.7
LCD FPC
12