Technical Data - Rangemaster Classic Deluxe 110 Dual Fuel User's Manual & Installation Instructions

Hide thumbs Also See for Classic Deluxe 110 Dual Fuel:
Table of Contents

Advertisement

10. Technical Data

THIS COOKER IS CATEGORY: CatII 2H3+.
It is supplied set for group H natural gas. A conversion kit from NG to LP is available for the cooker.
INSTALLER: Please leave these instructions with the user.
DATA BADGE LOCATION: Cooker back, serial number repeater badge below oven door opening.
COUNTRY OF DESTINATION: GB, IE.
Connections
Gas (Rp ½ at rear right-hand side)
Natural Gas
Butane
Propane
Dimensions
Refer to 'Positioning the Cooker' .
Overall height
Overall width
Overall depth
Minimum space above hotplate
Ratings
Hotplate
Bypass Screw*
Wok burner
Large burner
Medium burner
Small burner
Ceramic Hob
Power rating
* The valves in this cooker are fitted with adjustable bypass screws. The cooker is supplied with the bypass screws set for
Natural gas. For LPG conversion the bypass screws must be screwed all the way down.
Oven Efficiencies
Ovens
Maximum power output @ 230 V 50 Hz
Energy efficiency class on a scale of A (more efficient) to G (less efficient)
Energy consumption based on standard load
Usable volume (litres)
Size
Time to cook standard load
Surface area of the grid
Grill
Maximum total electrical load at 230 V (approximate total including oven lights, oven fan, etc.): 10.8 kW.
57
40
32
28
Front element
Rear element
1.1 kW
2.3 kW
20 mbar
29 mbar
37 mbar
minimum 905 mm
607 mm to fascia; 670mm over handles
Natural Gas 20 mb
Injector
internal 78
3.5 kW
external 126
3.0 kW
134
1.7 kW
109
1.0 kW
75
1.1 kW
32
Electric
230 / 400 V 50 Hz
maximum 930 mm
1092 mm
650 mm
L.P. Gas
3.5 kW (246 g/h)
3.0 kW (210 g/h)
1.7 kW (119 g/h)
1.0 kW (70 g/h)
Left-hand Oven
Right-hand Oven
Multi-function
Forced Air Convection
3.7 kW
A
0.95 kWh
69
Large
41 minutes
1400 cm
2
Injector
internal 53
external 82
87
68
51
2.5 kW
A
0.90 kWh
69
Large
41 minutes
1400 cm
2

Advertisement

Table of Contents
loading

Table of Contents