Orizontal Nstallations; Startup Procedure & Adjustment - Goodman *MVM96 Installation Instructions Manual

Modulating gas furnace
Hide thumbs Also See for *MVM96:
Table of Contents

Advertisement

FILTER
ACCESS
DOOR
RETURN
DUCT
FILTER
SUPPORT
BRACKET
(Field Supplied)
Possible Upright Counterflow
Filter Locations
H
I
ORIZONTAL
NSTALLATIONS
Filters must be installed in either the central return register or in
the return air duct work.
S
P
TARTUP
ROCEDURE
Furnace must have a 115 VAC power supply properly connected
and grounded. Proper polarity must be maintained for correct
operation. In addition to the following start-up and adjustment
items, refer to further information in Operational Checks section.
100%
IGNITION
(80%)
78%
57%
2 MINS.
MIN.
Operation with Conventional 1-Stage Thermostat
(DIP switch selects 1-Stage heat)
Call for heat, thermostat energizes W1 on the furnace con-
trol board (W2 input is ignored).
After a successful Light Off Sequence and expiration of the
Ignition Stabilization Period:
The furnace control board adjusts the firing rate to
35% (low fire rate).
After 2 minutes, the furnace control board increases
the firing rate to 57% at a rate of 1% per second.
After 10 total minutes, the furnace control board
increases the firing rate to 78% at a rate of 1% per
second.
CENTRAL
RETURN
GRILLE
AIR FLOW
& A
DJUSTMENT
UNIT CALL FOR HEAT ENDS
10 MINS.
8 MINS.
After 20 total minutes, the furnace control board
increases to 100% at a rate of 1% per second for the
remainder of the call for heat.
The circulator fan is adjusted to the appropriate CFM,
corresponding to the current firing rate.
IGNITION
(80%)
70%
60%
50%
MIN.
Operation with Conventional 2-Stage Thermostat
(DIP switch selects 2-stage heat)
Call for 1st-Stage Heat - Thermostat contacts close R to W1.
After a successful Light Off Sequence and expiration of the
Ignition Stabilization Period:
The furnace control board adjusts to the low firing
rate.
After 2 minutes, the furnace control board increases
the firing rate to 50% for the next 8 minutes.
Thereafter, the furnace control board will increase
the firing rate 10%, at a rate of 1% per second,
every 10 minutes for the remainder of the call for
heat (See above figure).
The circulator fan is adjusted to the appropriate CFM,
corresponding to the current firing rate.
90%
IGNITION
(80%)
70%
60%
50%
MIN.
Operation with Conventional 2-Stage Thermostat
(DIP switch selects 2-stage heat)
37
10 MINS.
8 MINS.
2 MINS.
10 MINS.
8 MINS.
2 MINS.