NOTE: Option 5 must be completed before
attempting option 6
Option 06 How to change temperature offset.
The temperature displayed on the thermostat may not
match that of other temperature measuring devices in
the controlled space, because of its location.
The displayed temperature may be offset to bring it in
line with other devices.
To adjust the temperature, enter the user options,
select option 06.
The temperature may be offset by +/- 5 degrees by
pressing the + and – keys. Press > to accept the
desired change.
Option 07 How to restore the built in time
temperature programs.
NOTE: Enabling this function will lose any user
changes to the preset programs.
Enter user options, select option 07 and use + and –
keys to select desired option. Off = current programs
retained. On = restore factory program settings.
Press > to select the desired change.
The option 07 display automatically reverts back to
off.
Option 08 How to disable the OFF function.
To disable the OFF function, enter user options,
select option 08 and use + or – keys to select Off.
Press > to accept change.
It is now not possible to switch the Digistat OFF
using the + and- keys as previously described.
To enable the OFF function return to option 08 and
select ON. Press > to accept change.
Option 09 How to lock the key pad - Access
Protection Lock.
The access protection lock allows you to lock the
Digistat Optimiser so that it cannot have any adjust-
ments.
The default is OFF mode allowing you to adjust the
Digistat.
To Lock the Digistat settings enter the User Options
Menu Option 09 and select On and press > to
accept.
Once the User Options Menu is exited all buttons will
be locked.
To switch off the Protection Lock enter the User
Menu and change to OFF. Press > to accept.
Once the User Menu is exited all buttons will be free
to adjust.
OPERATING & INSTALLATION
8
INSTRUCTIONS
NOTE: To exit User Options press < and >
simultaneously for 3 seconds.
Special Note:
The following only applies when the Intelligent
delayed start feature is enabled.
Ask your installer for details
When the delay period is operating indicated by the
flame symbol flashing, pressing any button returns
the DT10RF Programmer/Optimising Programmer to
auto mode allowing normal button operation until the
next time/temperature event, when it will resume the
delay start mode or follows the Holiday, Manual,
Override or Off modes as selected.
Changes to the installer options and pre-set pro-
grammes must be made with the flame symbol not
flashing
What is Intelligent delayed start.
The Intelligent Delayed Start is an energy saving
feature which automatically reduces the warm up
time for the heating system.
As the weather becomes milder, Intelligent Start will
delay the heating start times so that the fuel is not
wasted bringing the room up to temperature earlier
than necessary.
NOTE: See page 13 for further information and
set up details.