Split system heat pump with air handling unit

Advertisement

Quick Links

SPLIT SYSTEM
HEAT PUMP WITH
AIR HANDLING UNIT
PH1S090
Heat Pump System that Saves Energy and Provides Outstand-
ing Heating and Cooling All Year
• all-season comfort in any climate
• high energy savings capability
• suitable for new construction or replacement
FEATURES/BENEFITS
System indoor and outdoor sections offer outstanding perfor-
mance in either the Cooling or Heating mode
HEAT PUMP SYSTEM ENERGY SAVINGS OPPORTUNITY —
Electrical energy consumption is always a prime concern when
selecting an air-conditioning system for a commercial applica-
tion. An easy, effective way to save energy is to install a heat
pump. Should your building plans call for one, consider a
matched PH1S/PF1B heat pump system. This system not only
provides highly efficient cooling, it also doubles as a clean, safe,
efficient source of heat. In fact, it is capable of delivering ap-
proximately 3 units of heat energy for each unit of electrical
power consumed.
HEAT PUMP UNIQUENESS — The outstanding performance
of this heat pump system is due to the heat pump's ability to ab-
sorb and transfer heat — from outdoors to indoors for heating,
and from indoors to outdoors for cooling.
VARIABLE REFRIGERATION CIRCUITING (VRC) — PH1S
UNITS — For that extra measure of heat pump performance,
variable refrigeration circuiting provides improved heat transfer.
The design combines check valves and fixed-bore refrigerant
metering to improve the circuiting of the outdoor coil. This cir-
cuiting achieves the best performance possible during both the
heating and cooling modes. The VRC feature provides three
valuable benefits that ordinary heat pump systems cannot
match:
• Improved heat transfer, resulting in a higher Coefficient of
Performance (COP), especially at temperatures below 47 F.
• Improved reliability, by ensuring the proper quality of refriger-
ant is flowing to the compressor.
• Faster coil defrosting.
PF1B090
PH1S APPLICATION VERSATILITY — Whether for a new ap-
plication or replacement, these split system heat pumps offer
time-proven performance for year-round comfort in any climate.
RUGGED LONG LIFE COMPRESSOR — PH1S UNITS —
Model PH1S outdoor sections are equipped with semi-hermetic
compressors, which are famous throughout the industry for their
reliability. These compressors have vane-type oil pumps with
positive oil pressure, an oil pressure regulating valve, class F
stator windings, capacity reduction, oil level sight glass, and
service valves. A Cycle-LOC™ device in the PH1S control box
holds the compressor offline if any operational or safety device-
trips the compressor. The unit can be reset manually at the
thermostat.
FEATURES TO CONSIDER, PH1S UNITS
Controls for Performance Efficiency — The PH1S090 unit of-
fers simple operating controls and components designed for
performance dependability. The semi-hermetic compressor is
engineered for long life and durability. The compressor includes
overload protection and compressor vibration isolation for fur-
ther enhancement of quiet operation. The high-pressure switch
protects the entire refrigeration system from abnormally high
operating pressures. A loss-of-charge switch is also provided to
protect the system against low charge conditions.
The unit also includes anti-short-cycling protection which pro-
tects the compressor from the damage that can be caused by
rapid compressor cycling. The 24-v control circuit transformer
permits quick, easy wiring of standard and programmable 24-v
thermostats.
Latest safety standards for PH1S090 units are assured through
UL (Underwriters' Laboratories) and UL, Canada approval.
The PH1S090 utilizes a state-of-the-art defrost board with field
configurable timed defrost cycles. The defrost board may be
easily configured for defrost cycles of 30, 50, or 90 minutes, de-
pending upon the application.
Form No. PDS PH1S.90.1
Model PH1S
With PF1B
7
1
Tons
2

Advertisement

Table of Contents
loading

Summary of Contents for Payne PH1S

  • Page 1: Features/Benefits

    HEAT PUMP SYSTEM ENERGY SAVINGS OPPORTUNITY — service valves. A Cycle-LOC™ device in the PH1S control box Electrical energy consumption is always a prime concern when holds the compressor offline if any operational or safety device- selecting an air-conditioning system for a commercial applica- trips the compressor.
  • Page 2: Table Of Contents

    REFRIGERATION CIRCUITING — PH1S UNITS The economizer accessory precisely controls the blend of out- Cooling Mode — During cooling, the PH1S outdoor coil con- door air and room air to achieve comfort levels. When the out- denses the hot gas through a converging series circuit. First the...
  • Page 3 COOLING AND HEATING CYCLES — TYPICAL FOR PH1S090 UNIT LEGEND C — Check Valve Closed O — Check Valve Open COOLING LEGEND C — Check Valve Closed O — Check Valve Open HEATING...
  • Page 4: Model Number Nomenclature

    MODEL NUMBER NOMENCLATURE PH1S P A 090 000 AA AA PH1S — Commercial Factory-Installed Options Split System Heat Pump Unit AA — No Options Voltage Designation E — 460-3-60 Design Variables P — 208/230-3-60 A — Minor Series Designation Nominal Tons Electric Heaters 090 —...
  • Page 5: Ari Capacities

    INDOOR SOUND AIRFLOW Hi-Temp Low-Temp UNIT UNIT RATING (Cfm) Net Cap. Net Cap. Net Cap PH1S PF1B (Bels) (Btuh) (Btuh) (Btuh) 3000 86,000 83,000 46,000 LEGEND Bels — Sound Level (1 bel = 10 decibels) Cap. — Total Net Capacity (1000 Btuh) Btuh Output COP —...
  • Page 6: Physical Data

    PHYSICAL DATA OUTDOOR UNIT INDOOR UNIT UNIT PF1B UNIT PH1S NOMINAL CAPACITY (Tons) ⁄ NOMINAL CAPACITY (tons) ⁄ OPERATING WEIGHT (lb) OPERATING WT (lb) Base Unit with TXV REFRIGERANT (R-22) Plenum Operating Charge (lb)* 19.5 FANS COMPRESSOR 06DA818 Qty...Diam. (in.) 1...15...
  • Page 7: Accessories - Outdoor Unit

    ACCESSORIES — OUTDOOR UNIT ACCESSORIES — INDOOR UNIT Motormaster® III head pressure control operates in cooling Two-row hot water coils have ⁄ -in. diameter copper tubes mode at outdoor temperatures below 55 F. The Motormaster III mechanically bonded to aluminum plate fins. Coils have non- control varies the speed of the outdoor-fan motor to maintain ferrous headers.
  • Page 8: Dimensions - Outdoor Unit

    DIMENSIONS — OUTDOOR UNIT DIMENSION CHART ELECTRICAL CONNECTIONS UNIT WITH ALUMINUM-FIN COIL CONNECTION SIZES UNIT DIM. A DIM. B ⁄ Dia. [35] Field Power Supply Hole 1 -8 1 -5 2 Dia. [51] Power Supply Knockout PH1S090 [508.0] [431.8] ⁄ Dia.
  • Page 9: Dimensions - Indoor Unit

    DIMENSIONS — INDOOR UNIT NOTES: 1. Dimensions in [ ] are in millimeters. Direction of airflow. 3. Recommended clearance: • Rear: 3 • Front: 2 -6 • Right Side: 2 -6 • Left Side: 2 -6 • Local codes or jurisdiction may prevail. 4.
  • Page 10: Selection Procedure

    DIMENSIONS — INDOOR UNIT (cont) PF1B090 With Electric Heater Accessory SELECTION PROCEDURE (with example) I DETERMINE COOLING AND HEATING LOAD III DETERMINE THE HEATING CAPACITY OF SELECTED REQUIREMENTS. SYSTEM. Total Cooling Load (TC) ....86,000 Btuh Enter the Combination Ratings Net Capacities —...
  • Page 11: Performance Data

    PERFORMANCE DATA NOMINAL CAPACITIES OUTDOOR UNIT INDOOR UNIT AIRFLOW GROSS COOLING NET HEATING PH1S PF1B (Cfm) CAPACITY (Btuh) CAPACITY (Btuh) 3000 89,000 83,000 NOTES: 2. Net heating capacity is based on 70 F db air entering indoor unit and 1. Gross cooling capacity is based on 67 F wb, 80 F db air entering in- 47 F db, 43 F wb air entering outdoor unit.
  • Page 12 PERFORMANCE DATA (cont) COMBINATION RATINGS (cont) NET CAPACITIES — HEATING INDOOR UNIT ACCESSORY COILS — HYDRONIC HEATING CAPACITIES PH1S090 WITH PF1B090 Temp (F) Temp Air Entering Outdoor Unit (F) 1-ROW 2-ROW Air Ent Airflow UNIT AIRFLOW STEAM* HOT WATER COIL† Indoor (Cfm) PF1B...
  • Page 13: Performance Data

    PERFORMANCE DATA (cont) INDOOR UNIT FAN PERFORMANCE DATA — 1.4-2.4 ESP EXTERNAL STATIC PRESSURE (in. wg) UNIT AIRFLOW PF1B (Cfm) 2,250 1.06 1.16 1.27 1001 1.37 1042 1.47 2,600 1.22 1.33 1.43 1027 1.54 1067 1.65 3,000 1.43 1.54 1017 1.65 1058 1.76...
  • Page 14: Typical Piping And Wiring

    TYPICAL PIPING AND WIRING LEGEND NOTES: 1. All piping must follow standard refrigerant piping techniques. LLSV — Liquid Line Solenoid Valve 2. All wiring must comply with applicable local and national codes. — National Electrical Code 3. Wiring and piping shown are general points-of-connection guides —...
  • Page 15: Electrical Data

    ELECTRICAL DATA OUTDOOR UNIT VOLTAGE RANGE COMPR FAN MOTORS POWER SUPPLY UNIT V-PH-HZ No. of Min Ckt MOCP Fans Amps (Amps) 208/230-3-60 31.5 42.5 PH1S090 460-3-60 15.7 21.0 LEGEND — Full Load Amps — Locked Rotor Amps MOCP — Maximum Overcurrent Protection (Fuse Only) —...
  • Page 16: Electrical Data

    ELECTRICAL DATA (cont) ELECTRIC HEATER DATA — INDOOR UNIT ELECTRIC HEATER(S) HEATER MOTOR Nom. Actual Capacity (kW) V-Ph-Hz MCA* MOCP* PART NO. Cap. Stage 1 Stage 2 Total (kW) 2.4† 11.0 — 10.4 26.8 208-3-60 — 10.4 20.3 CAELHEAT001A00 2.4† 11.0 —...
  • Page 17: Controls

    CONTROLS SEQUENCE OF OPERATION — PH1S090 OUTDOOR UNIT Heating — On a call for heat, thermostat makes circuits R-Y WITH PF1B090 INDOOR UNIT — When power is supplied to and R-G. When compressor time delay (5 ± 2 minutes) is com- unit, the transformer (TRAN) is energized.
  • Page 18 TYPICAL CONTROL WIRING SCHEMATIC (cont) PH1S090 — 208/230-3-60, 460-3-60...
  • Page 19: Application Data

    TYPICAL CONTROL WIRING SCHEMATIC (cont) PF1B APPLICATION DATA OPERATING LIMITS GENERAL Maximum cooling load ......115 F Select equipment to match or to be slightly less than peak load.
  • Page 20 The recommended valve is Sporlan model CB14S2 (5/8-in. UNIT LINE Line Size (in. OD) ODF, 7/8-in. ODM). This solenoid valve requires Sporlan part PH1S (in. OD) no. MKC-2 coils that must be purchased locally. Wire the sole- noid valve in parallel with the compressor contactor coil. ⁄...
  • Page 21 APPLICATION DATA (cont) STANDARD FAN MOTOR DATA — INDOOR UNIT FIELD-SUPPLIED AND INSTALLED MEDIUM-STATIC 208/230-1-60, 208/230-3-60 AND 460-3-60 MOTORS DRIVE DATA UNIT UNIT PF1B PF1B Speed (rpm) 1725 MOTOR DRIVE Motor Pulley Pitch Diameter 3.4-4.4 Frame (NEMA) FAN DRIVE Shaft Dia (in.) ⁄...
  • Page 22: Guide Specifications - Ph1S090 Outdoor Unit

    GUIDE SPECIFICATIONS — PH1S090 OUTDOOR UNIT C. Fan: SPLIT-SYSTEM HEAT PUMP OUTDOOR UNIT 1. Propeller fan shall be directly driven by weather-proof HVAC GUIDE SPECIFICATIONS— SECTION 15678 motors. Fan motor bearings shall be permanently SIZE RANGE: 50,000 to 83,000 Nominal Btuh Heating lubricated.
  • Page 23 GUIDE SPECIFICATIONS — PH1S090 OUTDOOR UNIT (cont) G. Electrical Requirements: 1. Factory supplied and installed transformer shall pro- 2. Outdoor Thermostat: vide 24 v control voltage. Adjustable control shall activate electric heaters in stages to provide supplemental heat. Range: 2. All power and control circuit wiring shall comply with −30 F to 90 F.
  • Page 24: Guide Specifications - Indoor Unit

    GUIDE SPECIFICATIONS — INDOOR UNIT SPLIT SYSTEM HEAT PUMP INDOOR UNIT 3. Unit shall contain PVC condensate drain pans for both (Air-Handling Unit) vertical and horizontal applications. Drain pans shall have connections on right and left sides of unit to fa- HVAC GUIDE SPECIFICATIONS—...
  • Page 25 GUIDE SPECIFICATIONS — INDOOR UNIT (cont) 5. Return Air Grille: factory-supplied thermostat; economizer dampers shall open when outdoor air enthalpy is suitable for Grille shall be factory supplied for field installation on free cooling. Economizer shall include enthalpy con- the unit’s return air opening. trol and damper actuator.
  • Page 28 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE UNIT MUST BE INSTALLED IN ACCORDANCE WITH INSTALLATION INSTRUCTIONS Copyright 1998 Payne Heating & Cooling Printed in U.S.A. 3/98 CATALOG NO. 52PH-1S0...