four-pin optional sensor harness
RED wire
The red wire supplies constant power to the optional sensor.
BLACK wire
The black wire supplies ground to the optional sensor.
BLUE, GREEN wires
The blue and green wires are multiplex inputs. They are both tied to the same zone.
If an input of less than 0.8 seconds is supplied to either wire the Warn-Away
®
response will occur. An input longer than 0.8 seconds to either wire will initiate the
triggered sequence and report zone 4. This port can be used for optional sensors such
as: the 506T—glass breakage sensor, or the 508D—field disturbance sensor.
dealer master control loop
This 2-pin black connector when removed from the control module will reset the system
back to allow the full set of customer settings and remove the dealer remote from memory.
© 2003 directed electronics, inc.
18