Door Lock Harness Wire Connection; Guide; Plug-In Harnesses; Integrated Led/Valet Switch - Directed Electronics AM5 Installation Manual

Security system
Hide thumbs Also See for AM5:
Table of Contents

Advertisement

H2/6 VIOLET/BLACK (-) 200 mA channel 4 output: This wire supplies a (-) 200 mA
output whenever the button on transmitter programmed for channel 4 is pressed. This
output is used to control optional accessories.
I I M M P P O O R R T T A A N N T T ! ! Zones 2 and 4 are shunted when this channel becomes acttive. Zones
2 and 4 reactivate 5-seconds after this output ceases.
H2/7 YELLOW/BLACK no function.
door lock harness wire connection guide
___
GREEN
H3/A
___
H3/B
___
BLUE
H3/C
The control module can control 2 common power door lock types without any addition-
al parts. With certain verhicles, or if an actuator is to be installed, either a 451M Door
Lock Relay Satellite or two relays will be required. Refer to TechTips document 1041.

plug-in harnesses

integrated LED/Valet
®
The integrated LED/Valet
switch should be accessible from the driver's seat. The
Valet
part of the integrated LED/Valet
®
the unit. Check for rear clearance before drilling a 5/16-inch hole and mounting the
switch. The LED part of the integrated LED/Valet
into the white port on the side of the unit. Make sure the LED wires are not shorted to
ground as the LED will be damaged.
data port—Bitwriter
®
The black three-pin port can be used for programming the unit or to accommodate a
serial controller. The Bitwriter
© 2003 directed electronics, inc.
(-) Lock, (+) Unlock Output
(-) Unlock, (+) Lock Output
®
switch
switch plugs into the blue port on the side of
®
®
switch operates at 2V DC and plugs
®
is available for programming through this port.
Not Used